Elmo Rietschle F-RB
Elmo Rietschle F-RB — Compressors & Blowers.
The F-RB is a 100% oil-less high-speed radial blower from Elmo Rietschle's F-Series, operating in vacuum or pressure/compression mode. It delivers suction capacity up to 3000 m³/h at vacuum or pressure up to 200 mbar, with shaft power up to 10 kW. Its oil-free design suits fuel cells, food packaging, centralised vacuum systems, water treatment, textiles and electronics.
Full specifications
| Operating principle mfr | 100% oil-less |
| Application mfr | Fuel cells, food packaging, centralised vacuum s |
| Suction capacity mfr | 0-3000 m3/h |
| Vacuum mfr | 0-200 mbar |
| Pressure mfr | 0-200 mbar |
| Country of manufacture mfr | Germany |
| Application area mfr | Vacuum and compression |
| Max suction capacity mfr | 3000 m3/h |
| Max vacuum mfr | 200 mbar |
| Max pressure mfr | 200 mbar |
| Power consumption at shaft mfr | 0-10 kW |
| Max power consumption at shaft mfr | 10 kW |
Description
Construction and positioning
- The F-RB is a high-speed radial blower (HSRB) built on an oil-less dry-running principle, eliminating any lubricant in the gas path.
- It is a single model code within the F-Series; no sibling variants are listed in the verified data, so selection is based on the performance envelope rather than a size ladder.
- The machine is manufactured in Germany and is intended for both vacuum and compression duty, making it a dual-mode unit in a system.
Performance behaviour
- Suction capacity spans 0–3000 m³/h, with maximum vacuum and maximum pressure each at 200 mbar.
- Shaft power consumption ranges 0–10 kW, so the drive and power supply must be sized for the upper bound.
- The brochure gives performance curves at operating frequencies of 167 Hz, 233 Hz, 300 Hz and 367 Hz; the extra-spec fields list both 167 Hz and 367 Hz as operating frequencies, so the actual duty point must be matched to the correct curve for the chosen frequency.
- No digitized curve points were supplied, so exact flow/pressure pairs at intermediate frequencies must be read from the printed curves in the brochure.
Installation and operation
- The document digest contains no sections on electrical connection, control, or mechanical installation, so those details are not available from the verified facts.
- The oil-less construction means no lubricant handling or oil-change regime is required in the process gas path.
- Because the unit can run in either vacuum or pressure mode, piping and instrumentation must be configured for the intended mode; the verified data does not specify changeover hardware.
Integration & Operating Notes
The maximum vacuum and maximum pressure are both 200 mbar. Operating beyond this limit risks mechanical damage or invalid process results, and the 0–3000 m³/h flow range must be evaluated together with the 200 mbar ceiling when selecting the duty point.
Power consumption at the shaft reaches 10 kW at the top of the range. The motor, variable-frequency drive and supply must be rated for this maximum continuous shaft power, and the operating frequency must be set to one of the published curve frequencies (167, 233, 300 or 367 Hz).
Performance curves are published for 167 Hz, 233 Hz, 300 Hz and 367 Hz. Because the extra-spec fields list both 167 Hz and 367 Hz as operating frequencies, the engineer must confirm which curve applies to the intended speed and read flow and pressure from that curve rather than interpolating across the full range.
The blower is 100% oil-less, so there is no lubricant to change or dispose of in the process gas path. Maintenance planning should focus on the bearings and drive system, but the verified documents do not specify service intervals, so the manufacturer's manual must be consulted for the actual schedule.
Selection & Integration Q&A
No sibling models are listed in the verified data, so the F-RB is selected on its own envelope: 0–3000 m³/h, 200 mbar vacuum or pressure, and 10 kW shaft power. If your duty point falls outside these limits, a different series or size is required.
The drive must deliver at least 10 kW at the shaft and operate at one of the published frequencies (167, 233, 300 or 367 Hz). The supply and VFD must be sized for the full 10 kW continuous shaft power, and the duty point read from the corresponding frequency curve.
The verified documents do not specify mounting orientation, ambient temperature or duty-cycle limits. The unit is oil-less and rated for continuous vacuum or pressure up to 200 mbar, but installation and environment details must be taken from the full instruction manual.
The F-RB is oil-less, so no lubricant changes are needed in the gas path. The verified data does not list service intervals, spare parts, cables or controls, so these must be confirmed with the manufacturer; base delivery should be assumed to exclude drive, cabling and controls.