Elmo Rietschle G-BH100
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle G-BH100

Elmo Rietschle G-BH100 — Side-Channel / Regenerative Ring Blowers.

The G-BH100 is a side-channel blower from Elmo Rietschle's G-Series, configured as a single-stage, voltage-range motor unit for 50/60/87/100 Hz operation. It is distinguished within the series by its compact frame size and IP55 (or higher) protection, making it suitable for continuous duty in industrial vacuum or pressure systems. Its primary purpose is to provide oil-free, contactless air movement in processes requiring moderate flow and pressure differentials.

Full specifications

Description

Construction and series positioning

The G-BH100 is a side-channel (regenerative) blower, using a rotating impeller to accelerate air radially and then decelerate it in a ring channel, generating pressure or vacuum without contacting parts. Unlike ATEX variants, this model is not certified for explosive atmospheres. The motor is insulation class F, and the unit is UL 507 and CSA 22.2 No. 113 approved.

Behavior under load and media

As a side-channel blower, the G-BH100 exhibits a steep pressure-flow characteristic: flow decreases as pressure differential rises, with a maximum pressure ratio limited by the number of stages (single-stage here). The curve is not provided in the verified facts. The blower is oil-free and handles air and non-aggressive gases; no process media specifications are given for this model, so compatibility with corrosive or particulate-laden media must be verified separately.

Installation, connection, and control

Installation requires rigid mounting to avoid vibration transmission, and the blower can be mounted in any orientation. Electrical connection must match the motor nameplate and include overload protection. The IP55 enclosure requires cable glands rated for the environment; it does not by itself qualify the unit for outdoor use. Control is typically via a contactor or frequency inverter; the latter enables speed control but must respect the motor's insulation class and cooling limits at low speeds. No specific control interface or I/O is documented for this model.

Integration & Operating Notes

Electrical
Motor must be protected by a properly sized overload relay

The overload relay must be set to the nameplate current for the actual supply frequency; failure to do so risks winding damage from sustained overcurrent. Verify the connection (star or delta) matches the supply voltage.

Product Overview, Electrical Data
Mounting
Avoid pipe strain on blower flanges

The blower housing is not designed to support external piping loads. Use flexible connectors or expansion joints on inlet and outlet to prevent misalignment and vibration transmission. Support piping independently to avoid cracking the cast housing.

Product Overview, Installation
Environment
IP55 rating requires intact seals and cable glands

The standard IP55 protection depends on the integrity of the terminal box gasket and cable entry. Use glands with matching IP rating and ensure the cover is properly tightened. IP55 does not by itself qualify the unit for outdoor use; UV, condensation, and corrosion must be addressed separately.

Product Overview, Protection Class
Process Limits
Maximum pressure differential is fixed by single-stage design

Exceeding the maximum pressure differential (e.g., by closing a valve on the discharge) will cause the blower to operate beyond its curve, leading to overheating and potential motor overload. Install a pressure relief valve or bypass to protect against overpressure.

Product Overview, Performance
Maintenance
Inspect and clean impeller and channel periodically

Dust buildup on the impeller and channel reduces performance and can cause imbalance. The service interval depends on the process air cleanliness; in dusty environments, inspect every 500 hours. Clean with compressed air or a soft brush; do not scrape. Bearings are sealed and require no lubrication.

Product Overview, Maintenance

Selection & Integration Q&A

When should I choose the G-BH100 over the larger G-BH1 or G-BH2?

Choose the G-BH100 when your required flow and pressure differential fall within its smaller envelope, typically for low-flow vacuum holding or aeration. The G-BH1 and G-BH2 offer higher capacity but larger footprint; the G-BH100 is more compact and lighter, simplifying mounting on small machines.

Can I use a standard variable frequency drive (VFD) with the G-BH100?

Yes, the voltage-range motor is suitable for VFD operation, but the drive must be configured with a V/f curve that respects the motor's insulation class F and cooling limits. At low speeds, the self-ventilation decreases, so continuous operation at low speed may require an external fan or derating; consult the motor manufacturer for specific limits.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the blower only. Flexible connectors, pressure relief valves, filters, and mounting feet are not included. A frequency inverter and motor protection switch must be provided by the installer.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
IR ER G Series Product Overview ENG
Datasheet ·2,3 МБ ·6 pp.
View PDF