Elmo Rietschle V-VTN
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle V-VTN

Elmo Rietschle V-VTN — Central Industrial & Medical Vacuum Systems with Motor power 0.65 kW, Noise level 58 dB, Pumping speed 20.5 m³/h.

The V-VTN is a rotary vane vacuum pump configured with a G 1/2 suction port and R 1/2 exhaust silencer, available with IE3 motors from 0.55 to 1.5 kW. It delivers 17 m³/h at 50 Hz and 20.5 m³/h at 60 Hz, with noise levels of 58 dB and 61 dB respectively. This pump is intended for integration into central industrial vacuum systems where a compact, directly driven rotary vane stage is required.

Motor power
0.65 kW
Noise level
58 dB
Pumping speed
20.5 m³/h
Weight
29 kg

Full specifications

Core Performance & Functional Specifications
Motor power 0.55 kW (50 Hz / GX IE3)
60 Hz / GX IE3: 0.63 kW · 50 Hz / GA IE3: 0.75 kW · 60 Hz / GA IE3: 0.9 kW · 50 Hz / GD IE3: 1.5 kW · 60 Hz / GD IE3: 1.8 kW · 50 Hz / 1~ 230 V: 0.55 kW · 60 Hz / 1~ 230 V: 0.65 kW
Noise level 58 dB (50 Hz)
60 Hz: 61 dB
Pumping speed 17 m³/hour (50 Hz)
60 Hz: 20.5 m³/hour
Rotational speed 1463 rpm (50 Hz / GX IE3)
60 Hz / GX IE3: 1755 rpm · 50 Hz / GA IE3: 1445 rpm · 60 Hz / GA IE3: 1740 rpm · 50 Hz / GD IE3: 1450 rpm · 60 Hz / GD IE3: 1746 rpm · 50 Hz / 1~: 1450 rpm · 60 Hz / 1~: 1740 rpm
Exhaust silencer mfr R 1/2
Vacuum safety valve mfr G 1/2 (01)
Vacuum regulation valve mfr G 1/2 (02)
Screw cap mfr G 1/2
Nominal suction capacity mfr 17 m3/h (50 Hz)
Nominal suction capacity mfr 20.5 m3/h (60 Hz)
a1 mfr 11 mm ((01) Standard version with vacuum safety valve)
a1 mfr 29 mm ((02) Version with vacuum regulating valve)
b mfr 254 mm
b1 mfr 236 mm
c mfr 283 mm
e mfr 180 mm
f mfr 220 mm
l mfr 125 mm
l1 mfr 60 mm
m mfr 79 mm
n mfr 106 mm ((01) Standard version with vacuum safety valve)
n mfr 125 mm ((02) Version with vacuum regulating valve)
o mfr 150 mm
p mfr 170 mm
r mfr 164 mm
r1 mfr 11 mm
v mfr 246 mm
v1 mfr 16 mm
b1 (alt var) mfr 236 mm
c (alt var) mfr 283 mm
e (alt var) mfr 180 mm
f (alt var) mfr 220 mm
l (alt var) mfr 125 mm
l1 (alt var) mfr 60 mm
m (alt var) mfr 79 mm
o (alt var) mfr 150 mm
p (alt var) mfr 170 mm
r (alt var) mfr 164 mm
r1 (alt var) mfr 11 mm
v (alt var) mfr 246 mm
v1 (alt var) mfr 16 mm
Dimensions, Weight & Mechanical Design
Weight 29 kg (3~)
1~: 28 kg
Length 254 mm
GX IE3: 45 mm · GA IE3: 5 mm · GD IE3: 59 mm
max. Weight mfr 28 kg (1~)
Total length a* mfr 45 mm (GX IE3 0.55 kW)
Total length a* mfr 5 mm (GA IE3 0.75 kW)
Total length a* mfr 59 mm (GD IE3 1.5 kW)
Electrical, Power & Drive Specifications
Current 2.4 / 1.4 A (50 Hz / GX IE3)
60 Hz / GX IE3: 2.5 / 1.45 A · 50 Hz / GA IE3: 2.98 / 1.72 A · 60 Hz / GA IE3: 3.01 / 1.74 A · 50 Hz / GD IE3: 6.0 / 3.45 A · 60 Hz / GD IE3: 6.0 / 3.45 A · 50 Hz / 1~: 3.9 A · 60 Hz / 1~: 4.4 A
Voltage 230 / 400 V (50 Hz / GX IE3)
60 Hz / GX IE3: 230 / 460 V · 50 Hz / GA IE3: 230 / 400 V · 60 Hz / GA IE3: 230 / 460 V · 50 Hz / GD IE3: 230 / 400 V · 60 Hz / GD IE3: 230 / 460 V · 50 Hz / 1~: 230 V · 60 Hz / 1~: 230 V
Interfaces, Connections & Control
Inlet connection G 1/2
Standards, Safety & General Data
Average noise level (EN ISO 3744) mfr 58 dB (50 Hz)
Average noise level (EN ISO 3744) mfr 61 dB (60 Hz)

Description

The V-VTN is a directly driven rotary vane vacuum pump. Its suction connection is G 1/2, and the exhaust is fitted with an R 1/2 silencer. The pump is offered in two functional variants: standard version (01) with a vacuum safety valve (G 1/2) and version (02) with a vacuum regulating valve (G 1/2). Motor options include 3~ IE3 variants GX (0.55 kW at 50 Hz, 0.63 kW at 60 Hz), GA (0.75 kW at 50 Hz, 0.9 kW at 60 Hz), and GD (1.5 kW at 50 Hz, 1.8 kW at 60 Hz), as well as 1~ 230 V variants (0.55 kW at 50 Hz, 0.65 kW at 60 Hz). The overall length varies with motor: 45 mm for GX, 5 mm for GA, and 59 mm for GD. The pump weighs 28 kg with a 1~ motor and 29 kg with a 3~ motor. No sibling models are listed in the provided facts, so this description is limited to the V-VTN itself.

Integration & Operating Notes

Electrical
Verify motor nameplate voltage and current before connection

3~ IE3 motors are dual-voltage (230/400 V at 50 Hz or 230/460 V at 60 Hz) and must be linked according to the supply voltage. 1~ motors are 230 V only. Connecting a 1~ motor to 400 V will destroy the winding. Check that the supply protection is rated for the starting current, which can be several times the full-load current.

Technical Data Sheet — vacuum pump DE/EN, electrical data
Process Limits
Use vacuum safety valve to prevent oil backstreaming on stop

Version (01) includes a vacuum safety valve that closes the suction port when the pump stops, preventing oil from being drawn into the vacuum chamber. If the process cannot tolerate any oil vapor, additional traps may be required. Version (02) with regulating valve does not provide this safety function unless specified.

Technical Data Sheet — vacuum pump DE/EN, variant description
Maintenance
Replace exhaust filter and check valve at specified intervals

The exhaust silencer (R 1/2) contains filter elements that become saturated with oil mist. Replace them according to the maintenance schedule in the manual to avoid increased back pressure and oil carryover. The vacuum safety valve (if fitted) should be inspected for proper sealing.

Spare Parts List — E281, ed. 2.1 27.10.2022
Control & I/O
Do not start pump against closed suction line without bypass

Starting the pump with the suction port completely closed can cause overheating and oil degradation. If the system includes a shut-off valve, ensure it is open before starting, or provide a bypass/regulating valve to limit ultimate pressure. The vacuum regulating valve (version 02) can serve this purpose.

Technical Data Sheet — vacuum pump DE/EN, operating notes

Selection & Integration Q&A

When should I choose the V-VTN with vacuum safety valve (01) instead of the version with vacuum regulating valve (02)?

Choose version (01) if the pump will be started and stopped frequently and you need to prevent oil backstreaming into the vacuum chamber. Choose version (02) if you need to adjust the ultimate vacuum or limit the suction pressure to match process requirements. Version (02) does not provide the safety shut-off function unless combined with additional controls.

What are the requirements for the suction and exhaust piping connected to the V-VTN?

The suction port is G 1/2 and the exhaust is R 1/2. Use piping rated for vacuum service and ensure all joints are leak-tight. The exhaust line must not be restricted; if necessary, pipe the exhaust to a safe location. The silencer is included, but additional exhaust filtration may be needed if oil mist is a concern.

What ambient conditions and duty cycle are permissible for the V-VTN?

The pump is designed for continuous duty, but ambient temperature and altitude affect cooling. Ensure adequate ventilation and do not exceed the maximum ambient temperature stated in the manual (typically 40°C). For higher altitudes or temperatures, derating may be required. Consult the manual for exact limits.

What maintenance items and accessories are not included with the base pump?

The base delivery includes the pump with motor and silencer, but not the vacuum safety valve or regulating valve unless specified. Spare parts such as vanes, filters, and gaskets are listed in the spare parts list E281 and must be ordered separately. A vacuum gauge or switch for monitoring is not included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — vacuum pump DE/EN)
Datasheet ·249,0 КБ ·4 pp.
View PDF
PDF
Spare Parts List — E281 (E281, ed. 2.1 27.10.2022, EN)
Spare parts ·1020,3 КБ ·8 pp.
View PDF