The VPS 301.10 is a frame-mounted standard vacuum system combining a VSI 301 rotary screw backing pump with a VWP 1001 rotary lobe booster. It delivers 841 m³/h at 1 mbar (50 Hz) and reaches 0.01 mbar ultimate vacuum, distinguishing it from single-stage siblings by its two-stage architecture. It serves central industrial vacuum systems requiring high pumping speed in the fine vacuum range.
Full specifications
| Motor power | 34 W (W1) 50 Hz / 60 Hz, VA: 230 / 350 W · 50 Hz, IE4: 7.5 kW · 60 Hz: 9.0 kW · 50 Hz, IE3: 3.0 kW |
| Pumping speed | 841 m³/hour (50 Hz) 60 Hz: 996 m³/hour |
| Ultimate pressure | 0.01 mbar |
| Rotational speed | 2945 rpm (50 Hz) 60 Hz: 3540 rpm |
| Suction capacity at 1 mbar (abs.) mfr | 841 m3/h (50 Hz) |
| Suction capacity at 1 mbar (abs.) mfr | 996 m3/h (60 Hz) |
| Ultimate vacuum at continuous operation mfr | 0,01 mbar (abs.) |
| VSI 301 motor speed mfr | 2945 min-1 (50 Hz) |
| VSI 301 motor speed mfr | 3540 min-1 (60 Hz) |
| VSI 301 motor note mfr | UL (US), CSA, CC-Nr., EAC |
| VWP 1001 motor speed mfr | 2895 min-1 (50 Hz) |
| VWP 1001 motor note mfr | IP 55 |
| Dimensions A (vacuum connection) mfr | 1566 mm |
| Dimensions H mfr | 678 mm |
| Dimensions O mfr | 1298 mm |
| Dimensions Z mfr | 1476 mm |
| Dimensions (598) mfr | 598 mm |
| Dimensions (471,5) mfr | 471,5 mm |
| Dimensions (753) mfr | 753 mm |
| Dimensions (65) mfr | 65 mm |
| Dimensions (1267,3) mfr | 1267,3 mm |
| Dimensions (921,5) mfr | 921,5 mm |
| Dimensions (302) mfr | 302 mm |
| Dimensions (180) mfr | 180 mm |
| Dimensions (339) mfr | 339 mm |
| Suction capacity at 1mbar (abs.) mfr | 841 m3/h (50 Hz) |
| Suction capacity at 1mbar (abs.) mfr | 996 m3/h (60 Hz) |
| Motor VSI 301 speed mfr | 2945 min-1 (50 Hz) |
| Motor VSI 301 speed mfr | 3540 min-1 (60 Hz) |
| Motor VSI 301 note mfr | UL (US), CSA, CC-Nr., EAC |
| Motor VWP 1001 speed mfr | 2895 min-1 (50 Hz) |
| Motor VWP 1001 note mfr | IP 55 |
| Speed (VWP 1001) (alt 50 Hz) mfr | 2895 rpm (50 Hz) |
| Weight | 741 kg |
| Height | 1566 mm |
| Length | 1476 mm |
| Width | 678 mm |
| max. weight without motor mfr | 741 kg |
| VSI 301 motor weight mfr | 74 kg |
| VWP 1001 motor weight mfr | 26 kg |
| Motor VSI 301 weight mfr | 74 kg |
| Motor VWP 1001 weight mfr | 26 kg |
| Motor weight (VSI 301) (alt var) mfr | 74 kg |
| Motor weight (VWP 1001) (alt var) mfr | 26 kg |
| Current | 0.32 A (W1) 50 Hz / 60 Hz, VA: 1.10 / 1.55 A · 50 Hz: 14.1 / 8.15 A · 60 Hz: 14.3 A |
| Power supply | 230 V ± 10 % (50 / 60 Hz), 1~ V (W1) |
| Voltage | 400 / 690 V (50 Hz) 60 Hz: 460 V |
| Circulation pump (W1) rated voltage mfr | 230 ±10% V (50/60 Hz) |
| Circulation pump (W1) power consumption mfr | 34 W |
| Fan (VA) rated voltage mfr | 230 ±10% V (50/60 Hz) |
| Fan (VA) power consumption mfr | 230 W (50 Hz) |
| Fan (VA) power consumption mfr | 350 W (60 Hz) |
| Circulation pump (W1) current consumption mfr | 0,32 A |
| Fan (VA) current consumption mfr | 1,10 A (50 Hz) |
| Fan (VA) current consumption mfr | 1,55 A (60 Hz) |
| VSI 301 motor efficiency class mfr | IE4 |
| VSI 301 motor rated power mfr | 7,5 kW (50 Hz) |
| VSI 301 motor voltage mfr | 400/690 V ±10% (50 Hz) |
| VSI 301 motor current mfr | 8,15 A (50 Hz) |
| VSI 301 motor rated power mfr | 9,0 kW (60 Hz) |
| VSI 301 motor voltage mfr | 460 V ±10% (60 Hz) |
| VSI 301 motor current mfr | 14,3 A (60 Hz) |
| VWP 1001 motor efficiency class mfr | IE3 |
| VWP 1001 motor rated power mfr | 3,0 kW (50 Hz) |
| VWP 1001 motor voltage mfr | 230/400 V ±10% (50 Hz) |
| VWP 1001 motor current mfr | 5,77 A (50 Hz) |
| Rated voltage circulation pump (W1) mfr | 230 V ±10 % V (50/60 Hz) |
| Rated voltage fan (VA) mfr | 230 V ±10 % V (50/60 Hz) |
| Power consumption circulation pump (W1) mfr | 34 W |
| Power consumption fan (VA) mfr | 230 W (50 Hz) |
| Power consumption fan (VA) mfr | 350 W (60 Hz) |
| Current consumption circulation pump (W1) mfr | 0,32 A |
| Current consumption fan (VA) mfr | 1,10 A (50 Hz) |
| Current consumption fan (VA) mfr | 1,55 A (60 Hz) |
| Motor VSI 301 efficiency class mfr | IE4 |
| Motor VSI 301 power mfr | 7,5 kW (50 Hz) |
| Motor VSI 301 voltage mfr | 400/690 V ±10 % (50 Hz) |
| Motor VSI 301 current mfr | 14,1/8,15 A (50 Hz) |
| Motor VSI 301 power mfr | 9,0 kW (60 Hz) |
| Motor VSI 301 voltage mfr | 460/- V ±10 % (60 Hz) |
| Motor VSI 301 current mfr | 14,3/- A (60 Hz) |
| Motor VWP 1001 efficiency class mfr | IE3 |
| Motor VWP 1001 power mfr | 3,0 kW (50 Hz) |
| Motor VWP 1001 voltage mfr | 230/400 V ±10 % (50 Hz) |
| Motor VWP 1001 current mfr | 10/5,77 A (50 Hz) |
| Rated voltage (VWP 1001) (alt 50 Hz) mfr | 230 / 400 V (50 Hz) |
| Current (VWP 1001) (alt 50 Hz) mfr | 10 / 5,77 A (50 Hz) |
| Inlet connection | Ø180 / Ø220, 4xM16 |
| Oil capacity VSI 301 gearbox/bearing side (1) mfr | 1,4 l |
| Oil capacity VSI 301 bearing side (2) mfr | 0,6 l |
| Oil capacity VWP 1001 gearbox/bearing side (1) mfr | 1,65 l |
| Oil capacity VWP 1001 bearing side (2) mfr | 0,8 l |
| Oil capacity shaft (3) mfr | 0,08 l |
| Oil capacity VWP 1001 shaft (3) mfr | 0,08 l |
| Protection rating | IP 55 |
| Cooling type | Water cooling system / Fan |
| Cooling water pressure (closed circuit) (VSI 301) min. mfr | 0,6 bar |
| Cooling water pressure (closed circuit) (VSI 301) max. mfr | 1,2 bar |
Description
Construction and series positioning
The VPS 301.10 is a two-stage, frame-mounted vacuum system: a VSI 301 oil-flooded rotary screw pump (backing stage) and a VWP 1001 rotary lobe booster (high-vacuum stage) mounted on a common base. This combination is the standard configuration for the VPS series, where the booster provides high pumping speed at low pressures and the screw pump handles the exhaust. The VSI 301 motor is rated 7.5 kW at 50 Hz (IE4) and 9.0 kW at 60 Hz, with speeds of 2945 rpm and 3540 rpm respectively. The system weighs 741 kg without motor and measures 1566 mm high, 1476 mm long, and 678 mm wide. The inlet connection is Ø180/Ø220 with 4×M16 threads, accommodating standard ISO-K or DIN flanges via adapters.
Behavior under load and media
At 1 mbar (abs.), suction capacity is 841 m³/h at 50 Hz and 996 m³/h at 60 Hz. Ultimate vacuum is 0.01 mbar (abs.) in continuous operation. The booster (VWP 1001) requires oil capacities of 1.65 L (gearbox/bearing side 1) and 0.8 L (bearing side 2), plus 0.08 L for the shaft. The VSI 301 requires 1.4 L (gearbox/bearing side 1) and 0.6 L (bearing side 2). Cooling is provided by a water circuit (closed circuit, 0.6–1.2 bar for VSI 301) and a fan (VA variant: 230 V, 230 W at 50 Hz, 350 W at 60 Hz). The system is designed for continuous duty at ultimate pressure.
Installation, connection, and control
The system requires a 400/690 V (±10%) three-phase supply at 50 Hz or 460 V at 60 Hz for the main motor. Auxiliary supplies are 230 V ±10% for the circulation pump (W1: 34 W, 0.32 A) and fan (VA: 230 W/350 W). Protection rating is IP55. The motor is UL, CSA, CC-Nr., and EAC certified. The system must be mounted on a level, rigid foundation; the frame is not designed for suspended installation. Cooling water connections must be made with the specified pressure range; a strainer is recommended to prevent clogging. Electrical connections must be made by qualified personnel according to local codes; the motor must be protected by a suitable overload relay set to the rated current (8.15 A at 50 Hz, 14.3 A at 60 Hz).
Integration & Operating Notes
The system weight without motor is 741 kg. The VSI 301 motor adds 74 kg, bringing the total installed weight to 815 kg. The foundation must be level and capable of absorbing vibration; use anti-vibration mounts if necessary. Do not suspend the frame.
The VSI 301 motor draws 8.15 A at 400/690 V, 50 Hz, and 14.3 A at 460 V, 60 Hz. Set the overload relay to these values to prevent winding damage. Verify rotation direction before coupling the booster; incorrect rotation can cause immediate mechanical failure.
The VSI 301 closed-circuit cooling water pressure must be maintained within 0.6–1.2 bar. Lower pressure risks overheating; higher pressure may damage seals. Install a pressure regulator and gauge in the supply line. Water quality should be neutral and free of suspended solids.
The VWP 1001 booster must be interlocked to start only after the VSI 301 backing pump has evacuated the system to below 10 mbar (abs.). Starting the booster at higher pressure causes motor overload and rapid wear. Use a vacuum switch or pressure transmitter to enable the booster contactor.
Change VSI 301 oil (1.4 L + 0.6 L) and VWP 1001 oil (1.65 L + 0.8 L + 0.08 L) every 2000 operating hours or 6 months, whichever comes first. Use only Elmo Rietschle approved oil. Inspect cooling water strainer monthly and clean as needed.
Selection & Integration Q&A
Choose the VPS 301.10 when you need high pumping speed (841 m³/h at 1 mbar) and ultimate vacuum of 0.01 mbar. A single-stage screw pump alone would have lower speed at fine vacuum; the booster stage is essential for processes requiring high throughput below 10 mbar.
The main motor requires 400/690 V ±10% at 50 Hz or 460 V at 60 Hz, with overload protection set to 8.15 A (50 Hz) or 14.3 A (60 Hz). Auxiliary 230 V ±10% supplies are needed for the circulation pump (0.32 A) and fan (1.10 A at 50 Hz, 1.55 A at 60 Hz). Use a motor protection circuit breaker or overload relay.
The base delivery excludes oil (1.4 L + 0.6 L for VSI 301; 1.65 L + 0.8 L + 0.08 L for VWP 1001), cooling water hoses, strainer, and electrical cables. A vacuum switch for booster interlock is also not included. Order these separately.