Eppendorf BioBLU ® f Single-Use Bioreactors - Single-Use Fermentors
Eppendorf BioBLU ® f Single-Use Bioreactors - Single-Use Fermentors — Bioreactors & fermenters.
The BioBLU f is the single-use fermentor variant within Eppendorf's BioBLU single-use bioreactor line, distinguished from the c (cell culture) and Stem Cell impeller versions by its fermentor-oriented configuration. It is a stirred-tank single-use vessel integrated into the DASGIP, BioFlo, or DASbox control platforms for microbial and cell-based upstream processes.
Full specifications
Description
Series positioning
- BioBLU single-use bioreactors are offered in three impeller/configuration variants: c (cell culture), f (fermentor), and Stem Cell. The f variant is the fermentor-oriented modification, intended for microbial fermentation duty rather than the low-shear cell-culture duty of the c variant.
- The BioBLU line sits inside Eppendorf's broader upstream portfolio alongside the reusable DASbox, DASGIP, BioFlo 120, BioFlo 320 plus, and BioFlo 720 systems; working volumes across the portfolio span 60 mL to 500 L, but no BioBLU f-specific volume is stated in the supplied facts.
Construction and control architecture
- Single-use stirred-tank design: the vessel is a disposable bag with integrated impeller, mounted on a reusable hardware base that provides agitation drive, temperature control, and sensor connections.
- Control is delivered through the DASware software family (control, design, connect), with BioCommand SCADA for supervisory control and BioNsight cloud for data handling. These are platform-level components, not vessel-level accessories.
Behavior and media
- No digitized curve points, matched performance specs, or media ranges were supplied for this model; do not assume gassing rates, kLa, or temperature limits from the brochure. Confirm these against the vessel-specific data sheet before sizing.
Integration & Operating Notes
The BioBLU f is not a stand-alone unit: agitation, temperature, and sensor loops are driven by DASGIP, BioFlo, or DASbox hardware running DASware. Confirm the controller's single-use vessel compatibility and the correct bag holder before ordering, since the vessel alone provides no control.
The f (fermentor) and c (cell culture) variants differ in impeller and intended duty; shear and mixing behavior are not interchangeable. Establish agitation and gassing setpoints from f-specific data, not from c-variant or Stem Cell impeller experience.
The bag and integrated impeller are disposable; between batches the reusable base, drive, and sensor ports are the serviceable items. Plan consumable inventory (vessels, sensors, tubing) separately from the capital hardware, as none of these are part of the base delivery.
Selection & Integration Q&A
Pick the f variant for fermentor duty, where the impeller and configuration are matched to microbial-style processes. Choose the c variant for low-shear cell culture, and the Stem Cell impeller version for stem-cell applications; the three are not interchangeable by setpoint alone.
A compatible Eppendorf platform (DASGIP, BioFlo, or DASbox) with the matching single-use holder, running DASware control; BioCommand SCADA and BioNsight are optional supervisory/data layers. The vessel itself supplies no drives or loops.
The supplied brochure digest gives no vessel-specific temperature, pressure, or cycle limits for the BioBLU f. Obtain the vessel data sheet for validated operating ranges and single-use shelf life before defining a duty cycle; do not infer limits from the 60 mL–500 L portfolio span.
The disposable vessel with integrated impeller, plus sensors and tubing, are per-batch consumables and are not part of the reusable base. The control platform and DASware licences are separate purchases; confirm the consumable list with Eppendorf for the specific f size.