Eppendorf BioBLU ® f Single-Use Bioreactors - Single-Use Fermentors
Eppendorf ·Made in Germany · In Active Production

Eppendorf BioBLU ® f Single-Use Bioreactors - Single-Use Fermentors

Eppendorf BioBLU ® f Single-Use Bioreactors - Single-Use Fermentors — Bioreactors & fermenters.

The BioBLU f is the single-use fermentor variant within Eppendorf's BioBLU single-use bioreactor line, distinguished from the c (cell culture) and Stem Cell impeller versions by its fermentor-oriented configuration. It is a stirred-tank single-use vessel integrated into the DASGIP, BioFlo, or DASbox control platforms for microbial and cell-based upstream processes.

Full specifications

Description

Series positioning

Construction and control architecture

Behavior and media

Integration & Operating Notes

Control & I/O
Vessel requires a compatible Eppendorf control platform

The BioBLU f is not a stand-alone unit: agitation, temperature, and sensor loops are driven by DASGIP, BioFlo, or DASbox hardware running DASware. Confirm the controller's single-use vessel compatibility and the correct bag holder before ordering, since the vessel alone provides no control.

Fermentors Bioreactors Brochure, Bioprocess Family
Process Limits
Do not transfer c-variant culture parameters to the f vessel

The f (fermentor) and c (cell culture) variants differ in impeller and intended duty; shear and mixing behavior are not interchangeable. Establish agitation and gassing setpoints from f-specific data, not from c-variant or Stem Cell impeller experience.

Fermentors Bioreactors Brochure, BioBLU variant descriptions
Maintenance
Single-use vessel is replaced per batch, not cleaned

The bag and integrated impeller are disposable; between batches the reusable base, drive, and sensor ports are the serviceable items. Plan consumable inventory (vessels, sensors, tubing) separately from the capital hardware, as none of these are part of the base delivery.

Fermentors Bioreactors Brochure, single-use bioreactor section

Selection & Integration Q&A

When should I choose the BioBLU f over the c or Stem Cell variants?

Pick the f variant for fermentor duty, where the impeller and configuration are matched to microbial-style processes. Choose the c variant for low-shear cell culture, and the Stem Cell impeller version for stem-cell applications; the three are not interchangeable by setpoint alone.

What control hardware and software must be in place before the vessel can run?

A compatible Eppendorf platform (DASGIP, BioFlo, or DASbox) with the matching single-use holder, running DASware control; BioCommand SCADA and BioNsight are optional supervisory/data layers. The vessel itself supplies no drives or loops.

What installation and duty-cycle limits apply to the single-use vessel?

The supplied brochure digest gives no vessel-specific temperature, pressure, or cycle limits for the BioBLU f. Obtain the vessel data sheet for validated operating ranges and single-use shelf life before defining a duty cycle; do not infer limits from the 60 mL–500 L portfolio span.

What is consumed per batch and what is not included in base delivery?

The disposable vessel with integrated impeller, plus sensors and tubing, are per-batch consumables and are not part of the reusable base. The control platform and DASware licences are separate purchases; confirm the consumable list with Eppendorf for the specific f size.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Fermentors Bioreactors Brochure Bioprocess Family Lets bioprocess toge
Brochure ·14,7 МБ ·28 pp.