No photo available yet
Eppendorf BioFlo ® 720 - Large-Scale Bioreactor
Eppendorf BioFlo ® 720 - Large-Scale Bioreactor — Bioreactors & fermenters.
The BioFlo 720 is a large-scale bioreactor control system for Thermo Scientific HyPerforma 5:1 single-use bioreactors from 50 L to 2000 L. This configuration is the 50 L total-volume single-use vessel variant, with interchangeable vessels and two gas supply/mixing lines. It serves as the controller and vessel platform for scale-up cell culture in mammalian, stem cell and insect applications.
Full specifications
| Bacteria/yeast/fungi | no |
| Dimensions (w × D × H) | 80,6 x 87 x 160,3 cm |
| Exhaust Condensation | Electric heater band |
| Gas Supply | 2 |
| Insect | yes |
| Interchangeable Vessels | yes |
| Mammalian/animal | yes |
| Number Of Parallel Units | Single unit |
| Stem Cells | yes |
| Total Volume | 50 |
| Validatable | yes |
| Vessels | Single-use vessels |
| Product Weight | 177 kg |
| Voltage | 200 – 240 V |
| Standard Gas Flow Rates | 0.01 |
| Standard Gas Mixing | 2 |
Description
Construction and positioning
- The BioFlo 720 is a control system plus single-use vessel platform, not a stirred-tank fermentor: the matched spec lists 'Single-use vessels' and 'interchangeable vessels: yes'.
- This card's matched total volume is 50 L; the brochure scope covers HyPerforma 5:1 SUBs at 50, 100, 250, 500, 1000 and 2000 L, so the 50 L figure is the vessel size of this configuration, not a series-wide rating.
- Physical envelope is 80.6 x 87 x 160.3 cm (W x D x H) at 177 kg; a single unit is specified (no parallel units).
- Cell-type support in the matched specs: mammalian/animal yes, stem cells yes, insect yes; bacteria-yeast-fungi no.
Gas and process behavior
- Two gas supply lines and two gas mixing lines are specified; the standard gas flow rate field reads 0.01 with no unit in the source, so no flow rating is asserted here.
- Exhaust condensation is handled by an electric heater band.
- No digitized curve points were supplied, so no oxygen transfer, kLa or control-response behavior is stated.
Control, installation and operation
- Electrical: 200–240 V range (nominal 220 V per SI field).
- The unit is marked validatable; no certificates were supplied in the facts, so no compliance claim beyond that flag is made.
- The attached brochure digest contains no actionable installation, connection or control-loop facts; installation specifics must come from the BioFlo 720 operating manual, which was not provided.
Integration & Operating Notes
The controller is qualified against Thermo Scientific HyPerforma 5:1 single-use bioreactors across the 50 L to 2000 L range; this configuration is the 50 L vessel. Fitting a non-5:1 or third-party vessel leaves mixing and gas-transfer behavior outside the documented scope and voids the scale-up basis.
Matched specs list mammalian/animal, stem cell and insect support as yes and bacteria-yeast-fungi as no. Microbial or yeast processes requiring high oxygen transfer and heat removal should not be scheduled on this configuration; use a fermentor-rated platform instead.
The matched electrical spec gives a 200–240 V range (SI nominal 220 V). Feeding the cabinet outside this window risks control and heater-band malfunction; confirm site voltage and breaker sizing against the 177 kg floor-standing cabinet before installation.
The vessel is a single-use HyPerforma SUB and is replaced per batch; the 50 L vessel, gas filters and tubing are consumables outside the durable cabinet delivery. Stock the correct 5:1 SUB size and exhaust heater-band spares before campaign start.
The matched specs call for two gas supply and two gas mixing lines. Site gas panels must provide both feeds at the required purity and pressure; the standard gas flow field (0.01) carries no unit in the source, so size mass-flow controllers from the operating manual, not from this card.
Selection & Integration Q&A
Pick the 50 L vessel for process development and pilot runs where the 0.3 L–2000 L tech-transfer path starts small; move to 100–2000 L SUBs on the same BioFlo 720 controller when bench data are locked and you need production-scale batches.
A HyPerforma 5:1 single-use vessel in the chosen size, two gas supply and two gas mixing feeds, and a 200–240 V supply. The exhaust heater band is part of the unit; vessel, filters and tubing are consumables ordered separately.
The single-use vessel is replaced each batch and is not part of the durable cabinet; gas filters and tubing are likewise consumables. No service-interval data appear in the supplied brochure digest, so set PM intervals from the BioFlo 720 operating manual.