Eppendorf Centrifuge 5418 R
Eppendorf Centrifuge 5418 R — Centrifuges.
The Eppendorf Centrifuge 5418 R is a refrigerated benchtop microcentrifuge with a single fixed-angle rotor, reaching 14,000 rpm and 16,873 × g. It is the refrigerated member of the 5418 series, distinguished by active cooling for temperature-sensitive pelleting. It is used for routine 1.5/2.0 mL tube separations in molecular biology workflows.
Full specifications
| Acceleration Time 1) | 13 s |
| Deceleration Time 1) | 13 s |
| Dimensions (w × D × H) | 30 x 46 x 25 cm |
| Max. Rcf | 16873 g |
| Max. Rcf With Fixed-angle Rotor | 16873 g |
| Rotational speed | 100...14000 rpm |
| Rotors available mfr | 1 |
| Height (with Open Lid) | 52 cm |
| Product Weight | 22 kg |
| Max. Power Consumption | 320 W |
Description
Construction and positioning
- Benchtop microcentrifuge with a single factory-fitted fixed-angle rotor; no rotor interchange is specified in the verified data.
- Refrigerated variant (R suffix) within the 5418 series; the non-refrigerated 5418 is the sibling for ambient-temperature work.
- Footprint 30 × 46 cm, height 25 cm closed (52 cm with lid open), 22 kg.
Drive and performance envelope
- Speed range 100–14,000 rpm, with maximum RCF 16,873 × g at the fixed-angle rotor.
- 320 W motor; acceleration and deceleration each quoted at 13 s (rotor-dependent, not further qualified).
- No published curve points; behavior across the range is not characterized in the verified facts.
Installation and operation
- The only attached document is an EU safety data sheet for refrigerant R134a (CAS 811-97-2), covering the cooling circuit substance; it contains no installation, control or maintenance instructions for the instrument.
- No certificates, applications or sibling model data were supplied; integration specifics beyond the above are not verifiable from the provided facts.
Integration & Operating Notes
The attached safety data sheet identifies the refrigerant as R134a (1,1,1,2-tetrafluoroethane, CAS 811-97-2, EC 212-377-0). Service or disposal of the cooling circuit must follow the regional requirements referenced in that sheet; no charge quantity or pressure is stated in the verified facts.
Verified data lists one rotor available and gives maximum RCF only for the fixed-angle rotor (16,873 × g). Do not assume compatibility with swing-out or other rotors from the wider Eppendorf range; confirm tube formats against the rotor actually fitted.
Selection & Integration Q&A
Choose the R when samples or downstream steps require temperature control during the run; the cooling circuit is the differentiator. For ambient-temperature pelleting where heat build-up is acceptable, the non-refrigerated sibling avoids the refrigerant circuit and its service obligations. Both share the 14,000 rpm / 16,873 × g envelope.
Plan for the 30 × 46 cm footprint, 22 kg mass and 52 cm open-lid height. The verified facts give no voltage, current or plug type, so the electrical supply must be confirmed against the unit's nameplate before installation; no compressed air or water services are indicated.
The verified documents contain no maintenance schedule, error-code list or accessory catalogue. The only attached document is the R134a safety data sheet, which addresses the refrigerant, not routine service. Rotor, adapters, tubes and any calibration or service parts must be specified separately; intervals are not stated in the supplied facts.
Treat them as nominal: the verified data does not state the rotor, load or speed at which 13 s applies, and no curve points are supplied. For reproducible protocols, time the actual run on the installed rotor rather than assuming 13 s across the 100–14,000 rpm range.