Eppendorf Centrifuge 5702/ 5702 R/5702 RH - Low-Speed Centrifugation
Eppendorf ·Made in Germany · In Active Production

Eppendorf Centrifuge 5702/ 5702 R/5702 RH - Low-Speed Centrifugation

Eppendorf Centrifuge 5702/ 5702 R/5702 RH - Low-Speed Centrifugation — Centrifuges.

The Centrifuge 5702 is the non-refrigerated base model of the 5702 family, a low-speed benchtop centrifuge with a 100–4,400 rpm range and 3,052 × g maximum RCF using swing-bucket rotors. It accepts six rotor types and up to 4 × 100 mL, and is distinguished from the R and RH siblings by the absence of active temperature control.

Full specifications

Core Performance & Functional Specifications
Acceleration Time 1) 19 s
Blood Collection Tubes 36 mm
Conical Tubes 20 mL
Deceleration Time 1) 19 s
Dimensions (w × D × H) 32 × 40 × 24 cm
Max. Rcf 3052 g
Max. Rcf With Fixed-angle Rotor 1900 g
Max. Rcf With Swing-bucket Rotor 3052 g
Rotational speed 100...4400 rpm
Soft Brake Function yes
Temperature range −
Rotors available mfr 6
Max. capacity mfr 4 × 100 mL
Timer mfr 0 – 99 min, with continuous run function
Dimensions, Weight & Mechanical Design
Footprint (dimensions W/o Front Panel, Wxd) 32 cm
Height (with Open Lid) 53 cm
Product Weight 19 kg
Electrical, Power & Drive Specifications
Max. Power Consumption 200 W
Voltage 230 V
Interfaces, Connections & Control
Power Plug power plug type F
Operating Conditions, Environment & Protection
Cooling non-refrigerated
Noise level 52 dB

Description

Construction and series positioning

Run behavior

Electrical and installation

Integration & Operating Notes

Electrical
230 V / type F supply required; no 115 V variant stated

The unit is specified for 230 V, 50–60 Hz with a type F (Schuko) plug and 200 W maximum consumption. Installations on 115 V mains or with non-type-F receptacles require an adapter or a different supply arrangement; the supplied facts list no alternative voltage.

Factory Specification Sheet
Process Limits
RCF ceiling depends on rotor type, not a single model maximum

Swing-bucket rotors reach 3,052 × g while fixed-angle rotors are limited to 1,900 × g. Programming a setpoint above the installed rotor's limit is not supported by the stated data; verify the rotor in use before setting speed.

Factory Specification Sheet
Process Limits
No active temperature control on this model

The 5702 is the non-refrigerated variant; the temperature range field is listed as '−'. Runs whose protocol depends on holding a set temperature (e.g. 4 °C) require the 5702 R or 5702 RH sibling rather than this unit.

Centrifugation Brochure Centrifuge 5702 5702 R 5702 RH

Selection & Integration Q&A

When should I choose the 5702 rather than the 5702 R or 5702 RH?

Choose the 5702 when runs are at ambient temperature and no setpoint cooling or heating is needed; it is the non-refrigerated member. If the protocol requires holding a temperature, the R (refrigerated) or RH (heated and refrigerated) sibling is required, since this model's temperature range is listed as '−'.

What rotor and tube formats can I combine with this centrifuge?

Six rotors are supported, including swing-bucket (up to 3,052 × g) and fixed-angle (up to 1,900 × g) types. Maximum capacity is 4 × 100 mL, and the unit accepts 20 mL conical tubes and blood-collection tubes up to 36 mm. Select the rotor before setting speed, because the RCF ceiling follows the rotor.

What maintenance, accessories, or consumables are not included in base delivery?

The supplied documentation digest does not specify a maintenance schedule, service intervals, or which rotors, buckets, adapters, and cables ship with the base unit. Rotors and buckets are catalogued separately in the brochure, so confirm the rotor/bucket configuration and any adapters at order time; no service-interval data is available in the provided facts.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Centrifugation Brochure Centrifuge 5702 5702 R 5702 RH Its Your Turn.p
Brochure ·5,2 МБ ·12 pp.
View PDF