The Eppendorf Reference® 2 single-button pipette is a multichannel air-cushion pipette available in 8- and 12-channel configurations, covering 20–1,200 µL depending on channel count. Its one-button operation distinguishes it from the multi-button Research® plus and electronic Xplorer® lines. It is intended for parallel liquid transfers in microplate workflows.

Full specifications

Core Performance & Functional Specifications
Pipetting Type Air-cushion system

Description

Construction and series positioning

Working principle and media

Operation and control

Integration & Operating Notes

Process Limits
Air-cushion design limits use to aqueous, low-viscosity liquids

Because the sample is held by an air cushion, volatile solvents (e.g. ethanol, acetone) can evaporate and drift the dispensed volume, while high-viscosity or foaming liquids aspirate unevenly. Pre-wet tips and slow pipetting are required; no viscosity or vapour-pressure correction data is supplied.

Liquid Handling Flyer, Air-cushion system description
Mounting
Fixed tip spacing must match the plate format

The 8- and 12-channel Reference® 2 have fixed nozzle spacing; they align with standard 96-well (9 mm pitch) or 384-well plates only if the channel count matches the plate column count. For variable spacing between tube racks and plates, the Move It® variant is required instead.

Liquid Handling Flyer, scope and variants
Maintenance
Calibration and service intervals are not defined in the flyer

The attached flyer digest contains no calibration frequency, cleaning procedure or spare-part list. The engineer must obtain the separate Reference® 2 operating manual for gravimetric calibration intervals, seal replacement and tip-ejector service before putting the unit into a regulated workflow.

Liquid Handling Flyer (no service section present

Selection & Integration Q&A

When should I choose the Reference® 2 single-button pipette instead of a Research® plus or Xplorer® multichannel?

Pick the Reference® 2 for simple, repetitive 8- or 12-channel plate transfers where one-button aspiration/dispensing/ejection reduces hand fatigue. Choose Research® plus if you need 16/24 channels or multi-button volume adjustment; choose Xplorer® or Move It® for electronic volume setting or adjustable tip spacing.

What adjacent labware and accessories must match the Reference® 2 for correct operation?

Tips must match the channel format and volume range (20–1,200 µL for 8/12-channel). The fixed nozzle pitch must align with the plate column spacing (9 mm for 96-well). No electronic controller, cable or power supply is used; the device is fully mechanical, so no interface compatibility applies.

Are there duty-cycle or environmental limits for the Reference® 2 documented in the attached manual?

The attached flyer digest lists no ambient temperature, humidity or duty-cycle limits. Only the air-cushion principle is stated. For autoclaving, chemical resistance and operating temperature, consult the separate Reference® 2 operating manual; do not assume the flyer's silence means unlimited conditions.

What maintenance and consumables are not included with the base Reference® 2 delivery?

The flyer digest does not list pipette tips, tip boxes, calibration certificates, seals or spare ejector parts as included. Tips are consumables to be ordered separately in the matching volume range. Calibration and seal replacement intervals are absent from the flyer and must be taken from the operating manual.