The Eppendorf Move It® Adjustable Tip Spacing Pipette is an 8-channel air-cushion pipette with a 1–20 µL working range and light pink color code. Its distinguishing feature is adjustable tip spacing, which allows the same pipette to transfer samples between vessels of different formats. It is used for parallel liquid handling in molecular biology and analytical workflows where well-to-well spacing changes.
Full specifications
| Color Code | light pink |
| Pipetting Type | Air-cushion system |
| Pipetting volume | 1...20 µL |
| Number Of Channels | 8 |
Description
Construction and positioning
- Mechanical air-cushion pipette with 8 channels and a 1–20 µL volume range.
- Light pink color code identifies the volume group within the Move It® line.
- The Move It® series also includes electronic (Xplorer® plus) and mechanical (Research® plus) variants in 4-, 6-, 8- and 12-channel configurations; this card covers only the 8-channel, 1–20 µL mechanical adjustable-spacing unit.
- Adjustable tip spacing is the defining modification: the channel block can be set to match different vessel pitches, unlike fixed-spacing multichannel pipettes.
Behavior and media
- Air-cushion system: the sample is aspirated by an air column, so tip fit and tip selection directly affect accuracy.
- The 1–20 µL range is the low-volume end of the series; higher-volume siblings (5–100 µL, 30–300 µL, 120–1,200 µL) cover larger transfers.
- No digitized curve points or calibration data were supplied for this model; performance figures must be taken from the factory specification sheet.
Installation, control and operation
- Mechanical operation: volume setting and tip-spacing adjustment are manual; no electrical supply, controller or I/O is required.
- The attached brochure digest contains no actionable installation, control or maintenance facts for this specific model; refer to the instrument manual for tip-spacing adjustment procedure and calibration instructions.
Integration & Operating Notes
Adjust the channel spacing to the target vessel pitch while the tips are empty and above the labware; changing spacing with liquid in the tips can displace the air cushion and cause volume errors or cross-contamination between channels.
The base unit ships without a calibration certificate, spare tip-ejector parts or a carrying stand; schedule factory or in-house gravimetric calibration at the interval defined by your quality system and order the correct 1–20 µL tip family separately.
Selection & Integration Q&A
Choose 8 channels for standard 96-well plates and 8-strip tubes where 8-fold parallelism matches the plate column count. A 4-channel unit suits 384-well quadrant work or narrow vessels; a 12-channel unit suits 384-well full-column transfers. The 1–20 µL range covers low-volume PCR and sequencing setups only.
Use epT.I.P.S.® tips in the 1–20 µL range; the brochure lists epT.I.P.S.® and epT.I.P.S.® 384 as the compatible tip families. The adjustable spacing must be set to the pitch of the source and destination vessels, so confirm that both plate or tube formats fall within the channel-block travel before purchase.
No: it is a mechanical air-cushion pipette, so no electrical connection, controller or I/O is required. The supplied brochure digest gives no environmental or duty-cycle limits for this model; observe the ambient temperature and humidity limits stated in the instrument manual and avoid autoclaving the body.
The base delivery does not include calibration service, a stand or spare seals; plan for periodic gravimetric calibration and replacement of tip-ejector and seal components per the manual. Consumables are the 1–20 µL epT.I.P.S.® tips, ordered separately in the matching rack format.