Eppendorf Pipet Helper ®
Eppendorf Pipet Helper ® — Pipettes.
The Eppendorf Pipet Helper is a mechanical, single-channel pipette controller using an air-cushion system for serological pipets from 0.1 to 100 mL. It is fully autoclavable and accepts third-party pipets, distinguishing it as an open, steam-sterilizable manual controller. It serves as the aspiration/dispensing interface between a serological pipet and the laboratory vacuum/pressure source.
Full specifications
| Autoclavable | yes |
| Consumables | Eppendorf Serological Pipets |
| Delivery Content | Pipette controller , Operating manual, Membrane filter |
| Open System (third Party Consumables) | yes |
| Operating Mode | mechanical |
| Pipetting Type | Air-cushion system |
| Pipetting volume | 0.1...100 mL |
| Number Of Channels | 1 |
Description
Construction and series positioning
- Mechanical operating mode with no electrical drive; aspiration and dispensing are generated manually via the controller's internal air-cushion system.
- Single-channel (number-of-channels: 1) design dedicated to serological pipets; no sibling models are listed for this series, so the Pipet Helper stands as the sole mechanical controller variant in the supplied facts.
- Open system: accepts third-party serological pipets in addition to Eppendorf Serological Pipets, so consumable choice is not locked to one brand.
Working range and media behavior
- Pipetting volume range 0.1–100 mL covers the full serological pipet scale from 0.1 mL to 100 mL; no digitized curve points are available, so no aspiration/dispensing rate or accuracy behavior can be stated.
- Air-cushion principle means the aspirated liquid never enters the controller body; a membrane filter is supplied as part of delivery content to protect the internal air path.
- Autoclavable construction allows steam sterilization of the controller between uses; the exact autoclave cycle parameters are not given in the supplied facts.
Delivery and operation
- Delivery content: pipette controller, operating manual, membrane filter. No batteries, chargers, stands, or wall mounts are listed.
- Because the unit is mechanical, no electrical connection, control I/O, or firmware is defined in the supplied facts; operation is limited to manual aspiration/dispensing and filter maintenance.
Integration & Operating Notes
A membrane filter is included in delivery content and sits in the air path between the pipet and the controller. It must be inspected and replaced according to the operating manual to prevent liquid or aerosol carryover into the controller body; the manual is the only supplied source for the replacement interval.
The unit is autoclavable, so it can be steam-sterilized rather than chemically disinfected. The supplied facts do not state temperature, pressure, or cycle duration; consult the operating manual before the first autoclave run to avoid deforming seals or the filter housing.
The controller is specified as an open system, so non-Eppendorf serological pipets can be fitted as long as they fall within the 0.1–100 mL range. This removes the need to stock a single brand of pipets, but fit and seal at the controller nose must be checked for each pipet type.
Selection & Integration Q&A
Choose the Pipet Helper when a mechanical, autoclavable, single-channel controller for 0.1–100 mL serological pipets is required and no electrical supply is available. The supplied facts list no sibling controller variants, so selection against neighbors cannot be resolved from this data set.
It requires serological pipets within 0.1–100 mL (Eppendorf Serological Pipets or third-party, since it is an open system) and the supplied membrane filter in the air path. No electrical supply, drive, or controller interface is defined because the unit is mechanical.
The supplied facts define no mounting hardware, ambient temperature range, or duty-cycle limit. The only stated environmental capability is autoclavability. Confirm bench placement and continuous-use limits in the operating manual before relying on the unit in a production or high-throughput setting.
Base delivery is the controller, operating manual, and one membrane filter. Replacement membrane filters are the recurring consumable; no stand, wall mount, or carrying case is listed. Autoclave cycles and filter replacement intervals are defined only in the operating manual.