Peter Huber Kältemaschinenbau RotaCool
Peter Huber Kältemaschinenbau RotaCool — Recirculating chillers with Noise level 59 dB.
The RotaCool is a space-saving L-design recirculating chiller with a 208–240 V 1~/2~ 50/60 Hz supply, built specifically for conventional rotary evaporators. Its -10…40 °C working range and 1 K stability distinguish it as a dedicated evaporator cooling thermostat rather than a general-purpose process chiller. It serves as the cooling source for condenser loops in laboratory rotary evaporation setups.
Full specifications
| Noise level | 59 dB(A) |
| Expansion volume | 1 l |
| Pump connection | M16x1 AG male |
| Pump speed adjustable | no |
| Pump type | Yes |
| Temperature range | -10...40 °C |
| Temperature stability | 1 K |
| Weight | 32 kg |
| Power supply | 208-240V 1~/2~ 50/60Hz |
| Controller | MPC |
| Temperature display | LED Display |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | I / NFL |
Description
Construction and series positioning
- The RotaCool is an air-cooled, natural-draft recirculating chiller in a space-saving L-design, with cooling capacity and circulation quantity adjusted to conventional rotary evaporators.
- No sibling models are listed in the verified facts, so positioning within the Rotacool series is limited to this single configuration.
- The unit uses R-290 (A3, H220) refrigerant, which carries flammability classification implications for handling and room requirements.
- Protection rating is IP20, restricting installation to dry indoor locations protected from water ingress.
Working behavior and media
- Temperature range is -10…40 °C with 1 K stability, displayed on an LED display and controlled by an MPC controller.
- The pressure pump delivers up to 14 l/min at 0.25 bar head; the suction pump delivers up to 10.5 l/min at 0.17 bar suction head. These figures must be matched against the external circuit resistance.
- Minimum filling capacity is 1.5 l with 1 l expansion volume, setting the minimum bath/loop volume.
- Cooling capacity is rated at 20 °C room temperature and may drop as ambient temperature rises; ambient must remain between 5 °C and 40 °C.
Installation and operation
- Supply is 208–240 V 1~/2~ 50/60 Hz with a minimum 10 A and maximum 16 A fuse. Voltage and frequency tolerances must be met simultaneously; for example, -5% voltage with +2% frequency is not allowed.
- Single/two-phase devices are delivered with a power cable and country-specific plug that must be specified when ordering.
- Pump connections are M16x1 male, requiring M16x1 female mating fittings.
- The unit is EMC Class A, Group 1 to EN55011, which may require additional measures in residential environments.
Integration & Operating Notes
The 208–240 V 1~/2~ 50/60 Hz supply must satisfy voltage and frequency tolerances at the same time; a combination such as -5% voltage with +2% frequency is explicitly not allowed. Verify the actual supply envelope before connection, because a supply that appears acceptable on each parameter alone may still be outside the combined allowed range.
Single/two-phase devices are delivered with a power cable and a country-specific plug. The plug type must be stated when ordering; otherwise commissioning can be delayed until the correct plug or adapter is obtained.
The published cooling capacity is valid at 20 °C room temperature and may drop at higher ambient temperatures. Selection and duty planning must use the actual ambient conditions at the installation site, which must remain between 5 °C and 40 °C.
The unit uses R-290 (A3, H220), a flammable natural refrigerant. This affects handling, service access and room requirements; the installation location must be assessed accordingly rather than treated as an inert-refrigerant chiller.
With IP20 protection, the unit must be installed in a dry indoor location protected from water ingress and splashes. The air-cooled natural-draft refrigeration machine also needs adequate ventilation around the unit to avoid overheating and loss of cooling capacity.
Minimum filling capacity is 1.5 l and expansion volume is 1 l. The connected bath and loop must provide at least this inventory; underfilling risks pump operation and leaves insufficient expansion volume for the thermal fluid.
The pressure pump delivers up to 14 l/min at 0.25 bar head and the suction pump up to 10.5 l/min at 0.17 bar suction head. Verify that the connected loop's pressure drop is compatible with these heads before commissioning.
The equipment is classified EMC Class A, Group 1 to EN55011. In residential environments this may require additional measures to avoid disturbance; plan the installation location with this classification in mind.
Selection & Integration Q&A
The verified facts list no sibling models, so selection is limited to this configuration. Choose it when the application is a conventional rotary evaporator whose cooling capacity and circulation quantity match the unit's ratings; otherwise verify against the actual evaporator load.
Provide M16x1 female mating fittings for the M16x1 male pump connections, a loop with at least 1.5 l filling capacity plus 1 l expansion volume, and a 208–240 V 1~/2~ 50/60 Hz supply fused between 10 A and 16 A with simultaneous voltage/frequency tolerances.
Install in a dry indoor location with IP20 protection, ambient between 5 °C and 40 °C, and adequate ventilation for the air-cooled natural-draft refrigeration machine. Cooling capacity is rated at 20 °C room temperature and may drop at higher ambient.
The country-specific plug must be specified when ordering; mating M16x1 female fittings and the thermal fluid/loop inventory are not part of the unit. No maintenance schedule or accessory list is given in the verified facts, so service intervals cannot be stated.