Nabertherm GW 1660
Nabertherm ·Made in Germany · In Active Production

Nabertherm GW 1660

Nabertherm GW 1660 — Fusing.

The GW 1660 is a 1660-litre wire-heated chamber furnace rated to 900 °C, built with a 2300 × 1200 × 600 mm working chamber and connected to a 3-phase supply. Within the GW series it is the mid-size modification, positioned between smaller units and the GW 2200 for large-volume fusing and heat-treatment batches. Its primary role is bulk thermal processing where uniform temperature across a wide, low-profile chamber matters more than rapid cycling.

Nabertherm GW Series — Model Comparison & Selection

Model Chamber volume, LWeight, kgElectrical connectionMax temperature, °C
GW 1660 Current 166017803-phase900
GW 2200 220021603-phase900

Full specifications

Core Performance & Functional Specifications
Chamber volume 1660 l
Electrical connection 3-phase
Heating mfr 80
Inner dimensions (W × D × H) mfr 2300 × 1200 × 600 mm
Outer dimensions (W × D × H) mfr 3240 × 2030 × 1250 mm
Dimensions, Weight & Mechanical Design
Weight 1780 kg
Operating Conditions, Environment & Protection
Max temperature 900 °C

Description

Construction and series positioning

Thermal behaviour

Control and documentation

Integration & Operating Notes

Mounting
Floor loading of 1780 kg plus load must be checked before siting

The empty unit weighs 1780 kg and occupies a 3240 × 2030 mm footprint; the floor and any raised platform must be rated for the furnace plus the batch, and clearance for door swing and service access around the 1250 mm height must be reserved.

Factory Specification Sheet
Process Limits
900 °C is the ceiling for every batch and every thermocouple

No heating curves are supplied for this model, so soak times and ramp rates must be established empirically; loads and fixtures must be rated above the setpoint, and the 600 mm chamber height limits stack height for tall parts.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the GW 1660 rather than the GW 2200?

Pick the GW 1660 when a 1660-litre, 2300 × 1200 × 600 mm chamber at 900 °C covers the batch and the 1780 kg unit fits the floor plan. The GW 2200 is the larger sibling; choose it only when the bigger chamber is genuinely needed, since no other GW 2200 data is verified here.

What must be confirmed before connecting the GW 1660 to the plant electrical system?

Only the 3-phase connection is verified; voltage, current and connected load are not stated in the supplied facts. Obtain the nameplate data and size the feeder, protective device and isolator from it, and confirm the controller supply separately from the controller documentation.

What installation conditions does the documentation impose on siting the furnace?

The unit weighs 1780 kg with a 3240 × 2030 × 1250 mm envelope, so floor rating, transport route and door-swing clearance must be verified. No clearance or ventilation figures are printed in the supplied documents; these must be requested from the manufacturer before installation.

What is supplied with the base furnace and what must be ordered separately?

The supplied documents do not list a scope of delivery. Controller type, AMS2750F instrumentation, recorders and the MyNabertherm app linkage are described as options in the controller digest, so they must be specified on the order; no maintenance schedule or consumable list is included in the verified facts.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF