Nabertherm KB 400/12
Nabertherm ·Made in Germany · In Active Production

Nabertherm KB 400/12

Nabertherm KB 400/12 — Tilting Furnaces Electrically Heated Or Gas Fired.

The KB 400/12 is a gas-fired tilting furnace from Nabertherm's KB series, equipped with a TBN 1100 crucible and rated for a maximum temperature of 1200 °C. With a capacity of 1000 kg and a burner output of 450 kW, it is the largest model in the KB/12 line, positioned above the KB 150/12 and KB 360/12 for high-volume melting and holding duties. Its tilting design supports controlled pouring in foundry and metal-processing systems.

Nabertherm KB Series — Model Comparison & Selection

Model Weight, kgMax temperature, °C
KB 400/12 Current 36001200
KB 360/12 33001200

Full specifications

Core Performance & Functional Specifications
Crucible mfr TBN 1100
Capacityin kg mfr 1000
Burneroutput mfr 450
Melting performance3,6in kg mfr 4501
Consumptionmelting6kWh mfr 1.0 - 1.31
ConsumptionholdingLid closed mfr 19
Outer dimensions (W × D × H) mfr 1890 × 2150 mm
Dimensions, Weight & Mechanical Design
Weight 3600 kg
Operating Conditions, Environment & Protection
Max temperature 1200 °C

Description

Construction and series positioning

Performance and operation

Control and integration

Integration & Operating Notes

Process Limits
Do not exceed 1200 °C crucible temperature

The maximum temperature of 1200 °C is a hard limit for the furnace and crucible. Exceeding it risks crucible failure, melt contamination, and damage to the refractory. The control system must be configured with an over-temperature cutout set below this value, and the thermocouple type must be suitable for the range.

Factory Specification Sheet
Process Limits
Crucible TBN 1100 must match melt chemistry

The TBN 1100 crucible is specified for this model; using a different crucible may affect capacity, melting performance, and safety. The crucible material must be compatible with the alloy being melted to avoid chemical attack and premature failure. Consult the crucible supplier for melt-specific recommendations.

Foundry Catalog, Tilting Furnaces KB
Electrical
Burner output 450 kW requires adequate gas supply

The gas-fired burner is rated at 450 kW. The gas supply train must be sized for this input, with appropriate pressure regulation, shut-off valves, and leak testing. Electrical supply is only for controls and ignition; no main power rating is given in the available facts.

Factory Specification Sheet
Control & I/O
Controller options from 500 series and MyNabertherm app

The controller digest describes Nabertherm's 500 series and MyNabertherm app for process data storage and temperature uniformity. The KB 400/12 does not ship with a specific controller as standard; the choice affects data logging, AMS2750F compliance, and remote access. Specify the controller at order.

Prozesssteuerung englisch, Controller Functions
Maintenance
Crucible and refractory are wear parts; inspect regularly

The crucible and refractory lining are consumables subject to thermal cycling and chemical attack. Inspect for cracks, glazing, and thickness loss at scheduled intervals based on duty cycle. Replace the crucible per supplier recommendations; keep spare thermocouples and gaskets on hand.

Foundry Catalog, Maintenance Guidelines

Selection & Integration Q&A

When should I choose the KB 400/12 over the KB 360/12 or KB 150/12?

Choose the KB 400/12 for the highest capacity in the KB/12 line: 1000 kg melt and 450 kW burner output. The KB 360/12 offers lower capacity, and the KB 150/12 is for smaller batches. Select based on required melt volume per shift and available gas supply; the 400/12 demands the largest footprint (1890 × 2150 mm) and 3600 kg foundation load.

What gas supply and exhaust provisions are needed for the 450 kW burner?

The burner requires a gas train sized for 450 kW input, with pressure regulation, safety shut-off valves, and leak detection per local codes. Exhaust hood and flue must handle combustion products; the furnace should be installed under a vent hood. Electrical supply is only for controls and ignition, typically 230 V or 400 V three-phase, but verify with Nabertherm.

What consumables and accessories are not included in the base delivery?

The crucible TBN 1100 is listed as a specification, but consumables such as crucible, thermocouples, and refractory patching material are typically not included or are limited to initial fill. Controller, recorder, and MyNabertherm app are options. Gas train components and exhaust hood are site-supplied. Confirm the scope of supply with the order.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF