Nabertherm KBR 240/11
Nabertherm KBR 240/11 — Tilting Furnaces Electrically Heated Or Gas Fired.
The KBR 240/11 is a gas-fired tilting furnace with a recuperative burner, rated to 1100 °C and fitted with a TP 587 crucible holding 570 kg of aluminum melt. Within the KBR series (240/11 to 400/11), it is the smallest capacity variant, suited to melting and holding duty in foundry charging systems.
Full specifications
| Crucible mfr | TP 587 |
| Capacityin kg mfr | 570 |
| Burneroutput mfr | 390 |
| Melting performance2in kg mfr | 3201 |
| Consumptionmelting in kWh mfr | 1.1 - 1.41 |
| ConsumptionholdingLid closed mfr | 13 |
| Outer dimensions (W × D × H) mfr | 2300 × 1980 mm |
| Weight | 3600 kg |
| Max temperature | 1100 °C |
Description
Construction and series positioning
- Gas-fired tilting furnace with recuperative burner; crucible type TP 587, melt capacity 570 kg.
- Maximum furnace temperature 1100 °C; burner output 390 (unit as printed in the factory table).
- Outer dimensions 2300 × 1980 mm (W × D); unit weight 3600 kg.
- In the KBR recuperative series (KBR 240/11 through KBR 400/11), this is the lowest-capacity model; larger melt volumes require the higher-numbered siblings.
Thermal performance
- Factory melting performance is listed as 3201 kg (value as printed; verify unit and time basis with the factory before sizing).
- Energy consumption for melting is given as 1.1 – 1.41 kWh (basis as printed); holding consumption with lid closed is 13 (unit as printed).
- No digitized curves were supplied, so load-dependent melting rate and turn-down behavior cannot be plotted from verified data.
Control and documentation
- The attached controller digest covers the Nabertherm 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types; it does not print model-specific wiring for the KBR 240/11.
- The foundry catalog digest confirms the KBR recuperative range (240/11 to 400/11) but contains no installation details for this unit.
- No certificates or application notes were supplied; compliance and process approvals must be confirmed per project.
Integration & Operating Notes
The 1100 °C maximum is the ceiling for the furnace chamber and crucible; operating above it risks crucible and lining damage and invalidates melt quality assumptions. The controller setpoint and over-temperature protection must be configured so the limit cannot be exceeded during holding or superheat.
The unit weight of 3600 kg is the empty furnace; add the 570 kg melt capacity and tilting loads when specifying the foundation. The tilting axis and pouring side require free space beyond the 2300 × 1980 mm footprint for the ladle and operator access.
The controller digest describes the 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but prints no KBR-specific wiring. The project engineer must obtain the model-specific terminal plan and thermocouple schedule from the factory before panel design.
The TP 587 crucible and the recuperative burner are the components most exposed to thermal cycling and melt contact. Inspection intervals for crucible wall condition and burner/flue passages should be set from the operating manual; no interval is printed in the supplied digests, so the factory maintenance schedule must be requested.
Selection & Integration Q&A
Pick the 240/11 when the melt demand fits its 570 kg TP 587 crucible and 1100 °C ceiling. Higher-numbered KBR models (up to 400/11) exist for larger melt volumes; the 240/11 is the smallest in the recuperative range, so growth margin must be planned explicitly.
The factory table lists burner output 390 and melting consumption 1.1 – 1.41 kWh without a clear unit basis. The gas supply pressure, burner train and flue must be sized against the factory-clarified figures, and the recuperative air path must be ducted per the installation drawing.
The supplied digests do not list a scope of delivery. The TP 587 crucible is identified as the fitted crucible, but spare crucibles, thermocouples, controller options and the MyNabertherm app package must be ordered separately and confirmed against the factory order confirmation.