Nabertherm KC 180/14
Nabertherm KC 180/14 — Tilting Furnaces Electrically Heated Or Gas Fired.
The KC 180/14 is the largest SiC-rod-heated tilting melting furnace in the KC series, with a 1150 kg crucible capacity (TPC 412H) and 2302 kg melting performance. It reaches 1450 °C and is intended for foundry melting where the entire crucible is tilted for pouring. Its 187 kW nominal power and 3000 kg weight define the installation envelope.
Nabertherm KC Series — Model Comparison & Selection
| Model | Heating power, W | Weight, kg | Max temperature, °C |
|---|---|---|---|
| KC 180/14 Current | 99 | 3000 | 1450 |
| KC 150/14 | 66 | 2700 | 1450 |
Full specifications
| Heating power | 99 watt |
| Nominal power | 187 kW |
| Crucible mfr | TPC 412H |
| Capacityin kg mfr | 1150 |
| Melting performance3in kg mfr | 2302 |
| Outer dimensions (W × D × H) mfr | 2000 × 2070 × 1500 mm |
| Weight | 3000 kg |
| Max temperature | 1450 °C |
Description
Construction and series position
The KC 180/14 is a SiC-rod-heated tilting furnace for melting, the top size of the KC line (KC 20/14 through KC 180/14). It uses crucible TPC 412H with a capacity of 1150 kg and delivers a melting performance of 2302 kg. The outer dimensions are 2000 × 2070 × 1500 mm (W × D × H) and the furnace weight is 3000 kg. Compared with the sibling KC 150/14, this model is the larger crucible variant; select it when the melt batch exceeds the capacity of the KC 150/14.
Thermal and electrical behavior
Maximum temperature is 1450 °C. Nominal power is 187 kW. The matched heating-power entry of 99 W is inconsistent with the 187 kW nominal power and is therefore not used as a rating here. No digitized curve points are available, so heat-up and melt-rate behavior cannot be characterized beyond the stated melting performance.
Control and documentation
Attached document digests cover Nabertherm controller series 500 and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but they do not print model-specific settings for the KC 180/14. The foundry overview lists the KC range only as a selection guide. No installation, connection or operating specifics for this model are present in the supplied digests.
Integration & Operating Notes
The maximum temperature of 1450 °C is the upper process limit for this furnace. Operation above it risks damage to the SiC rod elements and the crucible; the controller setpoint and over-temperature protection must be configured so that the working temperature stays at or below this value.
The furnace weighs 3000 kg and holds a crucible of 1150 kg capacity; the tilting motion shifts the center of gravity during pouring. The foundation and surrounding steelwork must be rated for the combined static and dynamic load, and the tilting arc must be kept clear of obstructions.
The nominal power of 187 kW is the figure to use for supply cable, switchgear and protection sizing. The separate matched entry of 99 W is not consistent with this value and should not be used for electrical design; confirm the final connected load against the nameplate before ordering feeders.
Nabertherm controller series 500 and the MyNabertherm app provide process-data storage and AMS2750F instrumentation types according to the controller digest. The digest does not state which controller is fitted to the KC 180/14, so the actual control package and recording options must be confirmed on the order.
Selection & Integration Q&A
Pick the KC 180/14 when the required batch exceeds the KC 150/14 capacity: it takes crucible TPC 412H with 1150 kg capacity and 2302 kg melting performance at 1450 °C. The KC 150/14 is the smaller sibling for lower melt volumes.
Plan for 187 kW nominal power on the electrical side, and for a floor and tilting clearance rated for the 3000 kg furnace weight plus the 1150 kg crucible load. Confirm the actual connected load and control package against the nameplate, since the supplied digests give no model-specific connection data.
The process limit is 1450 °C maximum temperature; setpoints and over-temperature protection must keep the working temperature at or below this. The tilting arc must remain clear, and the foundation must carry the 3000 kg weight plus melt during pouring. No further environment data is given in the supplied documents.
The supplied documents do not specify service intervals, spare SiC rod elements, crucible TPC 412H spares, or controller cables for the KC 180/14. These must be requested from Nabertherm; the controller digest only confirms series 500 functions and MyNabertherm app data storage as available options.