Nabertherm L 40/11 BO
Nabertherm L 40/11 BO — Thermal Cleaning Ashing.
The L 40/11 BO is a 40-litre ashing furnace with integrated catalytic post-combustion, rated to 1100 °C and powered by a 11.7 kW three-phase connection. Its 320 × 490 × 250 mm chamber accepts up to 200 of organic substances at a maximum evaporation rate of 2.1, distinguishing it from the smaller L 9/11 BO sibling. It is intended for thermal cleaning and ashing processes where exhaust gases must be post-combusted before release.
Full specifications
| Chamber volume | 40 l |
| Chamber volume | 40 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Nominal power | 11.7 kW |
| Max. evaporation rate of organic substances mfr | 2.1 |
| Inner dimensions (W × D × H) mfr | 320 × 490 × 250 mm |
| Outer dimensions (W × D × H) mfr | 530 × 825 mm |
| Weight | 110 kg |
| Weight | 110 kg |
| Max. loading weight of organic substances mfr | 200 |
| Max temperature | 1100 °C |
| Max temperature | 1100 °C |
Description
Construction and series positioning
- The L 40/11 BO is the 40-litre member of the L ../11 BO ashing furnace series; the only listed sibling is the smaller L 9/11 BO.
- Integrated catalytic post-combustion is part of the model designation, so the exhaust treatment stage is built into the furnace rather than added downstream.
- Chamber dimensions are 320 mm wide × 490 mm deep × 250 mm high; outer dimensions are given as 530 × 825 mm (height not stated in the verified facts).
- Unit weight is 110 kg.
Process behaviour
- Maximum operating temperature is 1100 °C.
- The process envelope for organic loads is bounded by two separate limits: a maximum loading weight of 200 (unit not stated in the source) and a maximum evaporation rate of 2.1 (unit not stated in the source). Both must be respected simultaneously; neither substitutes for the other.
- No digitized curve points were supplied, so heat-up and post-combustion performance cannot be characterised from the available facts.
Electrical and control
- The furnace is connected to a three-phase supply with a nominal power of 11.7 kW.
- The attached document digests cover Nabertherm controller series 500 and the MyNabertherm app, process data storage, and AMS2750F instrumentation types, but they do not print model-specific wiring or terminal data for the L 40/11 BO. Controller configuration for this unit must therefore be confirmed against the order-specific documentation.
- The remaining attached digests (fiber optics glass, foundry, dental) describe other product lines and contain no actionable facts for this model.
Integration & Operating Notes
The 1100 °C maximum applies to the chamber; the catalytic post-combustion stage is part of the same model and its own permissible conditions are not stated in the verified facts. Any process recipe, including exothermic ashing of organic residues, must be validated so that the chamber limit is not exceeded during the load's own heat release.
Selection & Integration Q&A
Pick the L 40/11 BO when the charge needs the 40-litre, 320 × 490 × 250 mm chamber and the 200-unit organic loading limit at up to 2.1 evaporation rate. The L 9/11 BO is the smaller sibling; choose it only when its smaller chamber and lower load capacity still cover the batch, since the verified facts give no further L 9/11 BO data.
The furnace is a three-phase, 11.7 kW load, so the site supply, cable cross-section and protective device must be sized for that furnace load rather than for a generic 40-litre unit. The verified facts do not state voltage or current, so the exact rating must be read from the order-specific nameplate before the electrical design is fixed.
Two independent limits apply: a maximum loading weight of 200 and a maximum evaporation rate of 2.1. A heavy slow-evaporating charge and a light fast-evaporating charge can each breach one limit while satisfying the other, so every charge plan must be checked against both. The units for these values are not printed in the verified facts and must be confirmed on the factory data sheet.
The integrated catalytic post-combustion is part of the L 40/11 BO model designation, but the verified facts list no controller, recorder, sensor or cable as included. The generic controller digest covers series 500 and MyNabertherm app functions without model-specific terminal data, so controller, recorder and cabling must be confirmed as order options against the order confirmation.