Nabertherm L 9/11 BO
Nabertherm L 9/11 BO — Muffle furnaces.
The L 9/11 BO is a 9-litre ashing furnace with integrated exhaust gas cleaning, rated to 1100 °C and powered by a 7 kW three-phase connection. It is the smallest BO-series modification, distinguished by a 75 g organic load limit and 1.0 g/min evaporation rate, intended for controlled ashing of organic samples without releasing process fumes.
Full specifications
| Chamber volume | 9 l |
| Electrical connection | 3-phase |
| Nominal power | 7 kW |
| Max. evaporation rate of organic substances mfr | 1.0 |
| Inner dimensions (W × D × H) mfr | 230 × 240 × 170 mm |
| Outer dimensions (W × D × H) mfr | 415 × 575 mm |
| Weight | 60 kg |
| Max. loading weight of organic substances mfr | 75 |
| Max temperature | 1100 °C |
Description
Construction and series positioning
- The L 9/11 BO is a 9-litre chamber muffle furnace from the Nabertherm BO series (ashing furnaces with integrated exhaust gas cleaning, up to 1100 °C).
- Its chamber measures 230 × 240 × 170 mm (W × D × H); the outer dimensions are 415 × 575 mm (W × D), and the unit weighs 60 kg.
- Within the series, the sibling L 40/11 BO offers a larger chamber; the L 9/11 BO is the compact modification for small sample batches where bench space and load size are limited.
- The integrated exhaust gas cleaning is the defining architectural feature of the BO line: process fumes are handled inside the furnace rather than routed to an external scrubber.
Process behavior and limits
- Maximum operating temperature is 1100 °C. The furnace is designed for ashing organic substances, with a maximum loading weight of organic substances of 75 g and a maximum evaporation rate of 1.0 g/min.
- These two limits govern the batch size and heating ramp: exceeding either the load or the evaporation rate overloads the exhaust gas cleaning stage.
- No digitized curve points are available for this model, so no cooling or heating rate figures are stated here.
Electrical and control
- The furnace requires a 7 kW three-phase electrical connection. No voltage or frequency is specified in the verified facts; the site supply must be confirmed against the nameplate before installation.
- Controller and process documentation in the attached digests covers the Nabertherm 500 series and MyNabertherm app, but those documents do not print model-specific wiring for the L 9/11 BO; controller configuration must be taken from the unit's own manual.
Installation and operation
- The attached document digests (process control, fiber optics, foundry, dental) do not contain installation, connection or operating instructions specific to the L 9/11 BO. No mounting clearances, connection details or operating sequences can be stated from the verified facts.
Integration & Operating Notes
The integrated exhaust gas cleaning is sized for a maximum loading weight of 75 g of organic substances. Larger sample batches generate more fumes than the cleaning stage can handle, risking incomplete combustion and contamination of the exhaust path. Split samples or use the larger L 40/11 BO for heavier loads.
The maximum evaporation rate of organic substances is 1.0 g/min. The heating program must be ramped so that the sample does not release volatiles faster than this; a fast ramp on a wet or high-volatile sample can exceed the limit even when the total load is under 75 g.
The furnace is a 7 kW three-phase unit, but the verified facts do not state the operating voltage or frequency. The supply must be matched to the nameplate before connection; connecting a three-phase unit to an incompatible supply risks damage to the heating and control circuits.
Because exhaust gas cleaning is integrated, its condition depends on the organic load history. No service interval is given in the verified facts; the unit's own manual should be consulted for inspection and replacement intervals of the cleaning stage, and the 75 g / 1.0 g/min limits should be logged to anticipate servicing.
Selection & Integration Q&A
Pick the L 9/11 BO for small ashing batches within its 75 g organic load and 1.0 g/min evaporation limits, where its 9-litre chamber and 415 × 575 mm footprint fit the bench. Choose the L 40/11 BO when sample mass or throughput exceeds those limits.
It needs a 7 kW three-phase supply matched to the nameplate voltage and frequency, which the verified facts do not state. No controller, cable or exhaust duct accessories are listed as included; confirm controller compatibility and any extraction connection against the unit's own manual.
Operation is capped at 1100 °C with a maximum organic load of 75 g and evaporation rate of 1.0 g/min. The verified facts and attached digests give no ambient temperature, clearance or duty-cycle figures; these must be taken from the unit's manual before siting.
The integrated exhaust gas cleaning stage is the main service item, and its condition tracks the organic load history. No service interval, spare parts list or included accessories are given in the verified facts; the unit's manual should be consulted for the cleaning-stage inspection schedule and any consumables.