Nabertherm L(T) 9/11, LV(T) 9/11, LE 14/11
Nabertherm L(T) 9/11, LV(T) 9/11, LE 14/11 — Dental burnout furnaces.
The Nabertherm charging rack is a two-level loading accessory for L(T) 9/11, LV(T) 9/11, and LE 14/11 dental burnout furnaces, with each shelf measuring 202 × 202 mm and rated for 2.0 kg. It enables batch processing of dental restorations at up to 800 °C, distinguishing it from single-level loading within the series.
Full specifications
| Articel No. mfr | 6000079693 |
| Number of levels mfr | 2 |
| Dimensions shelf (level 1) in mm mfr | 45 |
| Outer dimensions (W × D × H) mfr | 215 × 219 × 98 mm |
| Max. weight per level mfr | 2.0 |
| Max temperature | 800 °C |
| Max temperature | 800 °C |
Description
Construction and positioning
- The charging rack is a dedicated accessory for the Nabertherm L(T) 9/11, LV(T) 9/11, and LE 14/11 burnout furnaces, providing two loading levels to increase batch capacity.
- Each shelf measures 202 × 202 mm (level 1 dimensions: 202 × 202 × 45 mm), and the maximum weight per level is 2.0 kg.
- Outer dimensions of the rack assembly are 215 × 219 × 98 mm (W × D × H), designed to fit within the furnace chamber.
- This rack is specific to the 9/11 and 14/11 series; it is not interchangeable with other Nabertherm furnace lines.
Behavior under load
- The rack supports up to 2.0 kg per level, allowing simultaneous firing of multiple dental restorations.
- The maximum operating temperature is 800 °C, consistent with the burnout furnace specifications.
- No digitized curve points are available; performance is tied to the host furnace's temperature profile.
Installation and operation
- The rack is placed inside the furnace chamber; no electrical connections are required.
- Loading and unloading should be performed with the furnace at ambient temperature to avoid thermal shock.
- The rack material and construction are suitable for repeated heating cycles up to 800 °C.
Integration & Operating Notes
Each level is rated for a maximum of 2.0 kg. Overloading can cause deformation of the rack or uneven heating, potentially damaging the furnace or the workload. Distribute weight evenly across the 202 × 202 mm shelf.
The rack is designed for use up to 800 °C. Exceeding this temperature may compromise the rack's structural integrity and affect the firing process. Ensure the host furnace's setpoint does not exceed this limit when the rack is loaded.
Regularly check the rack for warping or cracks, especially after exposure to high temperatures. Replace any damaged rack to maintain proper load distribution and prevent furnace damage.
Selection & Integration Q&A
Choose this rack when you need to process multiple dental restorations simultaneously in L(T) 9/11, LV(T) 9/11, or LE 14/11 furnaces. It doubles the loading capacity with two 202 × 202 mm shelves, each rated 2.0 kg, compared to single-level loading.
The rack is compatible only with L(T) 9/11, LV(T) 9/11, and LE 14/11 models. Ensure the furnace chamber dimensions accommodate the rack's outer dimensions of 215 × 219 × 98 mm. No electrical or control connections are required.
The rack is limited to a maximum temperature of 800 °C and a maximum load of 2.0 kg per level. It should be loaded and unloaded at ambient temperature to avoid thermal shock. Avoid exceeding these limits to prevent deformation.
Inspect the rack regularly for warping or cracks, especially after repeated firing cycles. No additional accessories are required for basic operation. Replace the rack if deformation is observed to ensure safe and even loading.