Nabertherm LCA 04/13 LB
Nabertherm LCA 04/13 LB — Dental combi furnaces.
The LCA 04/13 LB is a single-phase dental combi furnace for sintering cobalt-chromium frameworks, combining a 1300 °C maximum temperature with a 3.6 kW rating and 30 kg load capacity. Its 76 × 34 mm sintering bell and 126 mm charging area define a compact working envelope, while the 35-minute heating time supports rapid process cycles.
Full specifications
| Electrical connection | 1-phase |
| Maximum load | 30 kg |
| Nominal power | 3.6 kW |
| Work space sintering bellin mm mfr | 34 |
| Heating time mfr | 35 min |
| Outer dimensions (W × D × H) mfr | 350 × 500 × 780 mm |
| Work space annealing bellin mm mfr | 75 |
| Weight | 32 kg |
| Charging area in mm mfr | 126 |
| Charging area4 in mm mfr | 126 |
| Max temperature | 1300 °C |
Description
Construction and positioning
- The LCA 04/13 LB is a combi furnace dedicated to sintering cobalt-chromium dental restorations, with a maximum temperature of 1300 °C and a 3.6 kW single-phase electrical connection.
- The sintering bell measures 76 mm by 34 mm, and the charging area is 126 mm, giving a small, focused hot zone for dental frameworks.
- With a weight of 32 kg and outer dimensions of 350 × 500 × 780 mm, the unit is compact enough for bench-top or near-bench installation in a dental laboratory.
Behavior under load
- The furnace accepts a maximum load of 30 kg, which is well above typical cobalt-chromium framework batches, so the load limit is unlikely to be the restricting factor in normal use.
- A heating time of 35 minutes indicates the time required to reach working temperature; this should be considered when planning sintering cycles and furnace availability.
- No digitized curve points are available for this model, so temperature uniformity and control behavior cannot be characterized from the supplied data.
Control and operation
- The dental brochure lists the LCA 04/13 LB alongside the D580 controller, which is the standard control platform for this furnace family.
- The controller documentation covers process data storage and temperature uniformity instrumentation types, but no model-specific control parameters are printed for the LCA 04/13 LB.
- Installation, connection, and operating specifics beyond the electrical supply and dimensions are not detailed in the available document digests.
Integration & Operating Notes
The furnace draws 3.6 kW on a 1-phase connection. Verify that the branch circuit, wiring, and protective device are rated for this load and that the supply voltage matches the furnace nameplate; an undersized circuit will trip or cause voltage drop that affects heating performance.
The furnace is rated for a maximum load of 30 kg and a maximum temperature of 1300 °C. Exceeding either limit can damage the heating elements, insulation, or sintering bell, and may invalidate results. Plan batches and firing profiles to stay within both limits.
Selection & Integration Q&A
Choose the LCA 04/13 LB when the process is sintering cobalt-chromium frameworks and a 1300 °C maximum temperature with a 76 × 34 mm sintering bell is sufficient. For vacuum firing or pressing, the VL 01/12 LB or VL 01/12 LB Press are the respective alternatives; for burnout, the L(T) ../11 or LE ../11 series apply.
The available documents do not specify maintenance intervals or consumables for the LCA 04/13 LB. The D580 controller is referenced in the dental brochure, but whether it is included or optional is not stated. Consult the furnace manual for service schedules and accessory lists.