Nabertherm LHT 04/17 SW
Nabertherm ·Made in Germany · In Active Production

Nabertherm LHT 04/17 SW

Nabertherm LHT 04/17 SW — High-temperature furnaces.

The LHT 04/17 SW is a 4-litre high-temperature furnace with a 150 × 150 × 150 mm chamber, rated to 1750 °C and heated by a 3-phase connection. It is the SW (special) modification of the LHT 04/17 series, intended for combustion-loss determination and thermogravimetric analysis where a small, fast-cycling chamber is required.

Full specifications

Core Performance & Functional Specifications
Chamber volume 4 l
Electrical connection 3-phase3
Connected mfr 5
Heating time mfr 30 min
Inner dimensions (W × D × H) mfr 150 × 150 × 150 mm
Outer dimensions (W × D × H) mfr 655 × 370 × 890 mm
Dimensions, Weight & Mechanical Design
Weight 85 kg
Operating Conditions, Environment & Protection
Max temperature 1750 °C

Description

Construction and series positioning

Thermal behaviour

Control and operation

Integration & Operating Notes

Electrical
Three-phase supply and 5 connected conductors must be provisioned

The factory data list a 3-phase connection with 5 connected conductors. The electrical installer must confirm the site supply matches this configuration before commissioning; no voltage or current rating is printed in the verified facts, so the nameplate must be consulted.

Factory Specification Sheet
Process Limits
Do not exceed 1750 °C chamber temperature

The maximum temperature is 1750 °C. Operation above this limit risks damage to the heating elements and insulation; the controller setpoint and over-temperature protection must be configured so the chamber cannot exceed this value.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the LHT 04/17 SW rather than another furnace in the LHT 04/17 range?

No sibling models are listed in the verified facts, so a direct comparison cannot be made. The SW is documented as a 4-litre, 1750 °C, 3-phase unit; confirm chamber size and electrical supply against any alternative before selecting.

What supply and connection requirements must the electrical installer meet for this furnace?

The factory data specify a 3-phase connection with 5 connected conductors. Voltage and current are not printed in the verified facts, so the installer must read the nameplate and provide a matching three-phase supply before commissioning.

What maintenance schedule and accessories are defined for this model?

The verified facts contain no maintenance intervals, consumables or included accessories for the LHT 04/17 SW. The attached controller document covers the 500 series and MyNabertherm app but does not list furnace-specific service parts; these must be requested from the manufacturer.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF