Nabertherm NA 120/45 LS
Nabertherm NA 120/45 LS — Prozesse Unter Luft.
The NA 120/45 LS is a forced-convection chamber furnace with a 120-litre chamber (450 × 600 × 450 mm) and a maximum operating temperature of 450 °C, built to EN 1539 safety technology for processes under air with solvent release. It is the 120-litre modification of the NA/LS series, distinguished by its exhaust air flow rate of 100–120 and solvent-volume limits that scale with temperature. It is used for drying, curing and heat treatment where flammable volatiles must be safely removed from the work chamber.
Full specifications
| Chamber volume | 120 l |
| Heating power | 18 watt |
| Exhaust air flow rate mfr | 100 - 120 |
| Inner dimensions (W × D × H) mfr | 450 × 600 × 450 mm |
| Outer dimensions (W × D × H) mfr | 1250 × 1550 × 1950 mm |
| Max temperature | 450 °C |
Description
Construction and positioning
- The NA 120/45 LS is a forced-convection chamber furnace with a 120-litre working volume and inner dimensions of 450 × 600 × 450 mm; the outer envelope is 1250 × 1550 × 1950 mm (W × D × H).
- The LS designation denotes safety technology per EN 1539, intended for processes under air where solvents are released. The series spans forced-convection chamber furnaces up to 500 litres; this model is the 120-litre, 450 °C member.
- Heating power is listed as 18 W in the matched specification; this value is not consistent with a 120-litre furnace and is therefore not used for sizing or electrical planning.
Behaviour under load and media
- Maximum operating temperature is 450 °C. The exhaust air flow rate is given as 100–120 (unit not stated in the source).
- Solvent handling is temperature-dependent: the extra specifications list maximum solvent volumes of 51, 20, 9, 5 and 4 (unit not stated) under the label “Maximum volume of solvent in gat temperature”. Because the corresponding temperature steps are not printed, these values cannot be assigned to specific setpoints and must be taken from the original EN 1539 documentation before charging solvents.
- No digitized curve points are available for this model, so heat-up and uniformity behaviour cannot be quantified from the supplied facts.
Installation, control and operation
- The attached document digests do not contain actionable engineering facts for this model: the controller document covers the 500 series and MyNabertherm app without model-specific data, and the fiber optics, foundry and dental brochures do not address the NA 120/45 LS. Installation, connection and control specifics must therefore be taken from the model-specific instruction manual, which is not part of the supplied digests.
Integration & Operating Notes
The source lists five maximum solvent volumes (51, 20, 9, 5 and 4) under one label without the corresponding temperature steps. Before any solvent-bearing load is introduced, the applicable volume for the actual setpoint must be confirmed from the EN 1539 documentation; exceeding the limit for that temperature risks an explosive atmosphere in the chamber.
Selection & Integration Q&A
Choose the NA 120/45 LS when the workload fits the 450 × 600 × 450 mm chamber and the process needs EN 1539 safety technology at up to 450 °C with solvent release. Larger series members (up to 500 l) are for bigger batches; the 120-litre chamber is the deciding factor here.
The exhaust air flow rate must be held at 100–120 (unit not stated) whenever solvents are present. Ducting, extraction fan and any monitoring devices must be sized to maintain that flow, and the solvent charge must stay within the temperature-dependent volume limits.
None specific: the controller digest covers the 500 series and MyNabertherm app generically, and the other brochures do not address the NA 120/45 LS. Maintenance intervals, error codes and optional cables or recorders must be confirmed from the furnace instruction manual and order documentation.