Nabertherm NA 120/65
Nabertherm NA 120/65 — Forced Convection.
The NA 120/65 is a forced-convection chamber furnace with a 120-litre chamber (450 × 600 × 450 mm) rated to 650 °C, heated by a 12 kW element set on a 3-phase supply. Within the NA series it is the mid-volume, lower-temperature debinding modification, distinguished from the 250-litre and 850 °C siblings by its smaller chamber and reduced ceiling temperature. It is intended for uniform-temperature batch debinding and heat treatment where 650 °C is sufficient.
Nabertherm NA Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Max temperature, °C | Weight, kg |
|---|---|---|---|---|
| NA 120/65 Current | 120 | 3-phase | 650 | 280 |
| NA 250/85 DB200 | — | — | — | — |
Full specifications
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Chamber volume | 120 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating mfr | 12 |
| Heat-up time3 mfr | 90 |
| Cool-down time3 from Tmax mfr | 60 |
| Inner dimensions (W × D × H) mfr | 450 × 600 × 450 mm |
| Outer dimensions (W × D × H) mfr | 1030 × 1410 × 1535 mm |
| Weight | 280 kg |
| Weight | 280 kg |
| Weight | 280 kg |
| Weight | 280 kg |
| Weight | 280 kg |
| Max temperature | 650 °C |
| Max temperature | 650 °C |
| Max temperature | 650 °C |
| Max temperature | 650 °C |
| Max temperature | 650 °C |
Description
Construction and series position
The NA 120/65 is a forced-convection chamber furnace: a 120-litre working chamber measuring 450 mm wide × 600 mm deep × 450 mm high inside an outer envelope of 1030 × 1410 × 1535 mm, with a unit weight of 280 kg. The 12 kW heating set is wired for a 3-phase connection. Within the NA family it sits between the smaller NA 60/85 and the larger NA 250/85 and NA 250/85 DB200: it offers roughly half the chamber volume of the 250-litre units and a 650 °C maximum instead of 850 °C, so it is the choice when batch size is moderate and the process ceiling is below 650 °C.
Thermal behaviour
- Maximum working temperature: 650 °C.
- Heat-up time to temperature: 90 (as printed in the factory data).
- Cool-down from Tmax: two figures are printed in the same field, 240 and 60; because the source does not label which condition each belongs to, neither is asserted here as the model's cooling time.
- No digitized curve points were supplied, so no load-dependent or atmosphere-dependent performance is claimed.
Control and operation
The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and temperature-uniformity instrumentation per AMS2750F, plus recorder and controller options. These are controller-platform capabilities described in the digest; the specific controller fitted to the NA 120/65 is not stated in the verified facts and must be confirmed at order. The catalog digest places the NAT/NA forced-convection chamber furnaces in the up-to-900 °C class; the NA 120/65 itself is limited to 650 °C.
Integration & Operating Notes
The furnace is a 3-phase unit with a 12 kW heating set; the site supply, isolation and cable entry must be planned for that load and for the inrush of the heating contactors. The verified facts give the phase count and heating rating but not the operating voltage, so the actual voltage/frequency must be taken from the nameplate before ordering switchgear.
The NA 120/65 is rated to 650 °C, below the 850 °C ceiling of the NA 250/85 and NA 60/85 siblings. Processes requiring higher debinding temperatures must use those models; operating this chamber above its rating is outside the verified specification.
Selection & Integration Q&A
Pick the NA 120/65 when a 120-litre chamber (450 × 600 × 450 mm) and a 650 °C ceiling cover the batch. The NA 250/85 and NA 250/85 DB200 give 250 litres and 850 °C for larger or hotter loads; the NA 60/85 is the smaller 850 °C unit.
The furnace is a 3-phase unit with a 12 kW heating set, so the feed, isolation and contactors must be rated for that load. The verified facts do not state the operating voltage or frequency; read them from the nameplate before ordering switchgear.
The 500-series controllers, MyNabertherm app, process-data storage, AMS2750F uniformity instrumentation and recorder options are documented as controller-platform features; the fitted package for the NA 120/65 is not fixed in the verified facts and must be specified at order.