No photo available yet
Nabertherm NA 4000/45
Nabertherm NA 4000/45 — Forced Convection Furnaces.
The NA 4000/45 is a 4000-litre forced-convection chamber furnace with a 450 °C maximum temperature and 3-phase electrical connection. Its 1500 × 2200 × 1200 mm chamber and 6400-unit circulation distinguish it as the largest modification in the NA series, intended for bulk heat treatment where uniform air movement across large loads is required.
Nabertherm Forced Convection Chamber Furnaces from 1000 Liter electrically heated | Nabertherm Series — Model Comparison & Selection
| Model | Chamber volume, L | Max temperature, °C | Electrical connection |
|---|---|---|---|
| NA 4000/45 Current | 4000 | 450 | 3-phase |
| N 1500/85HA | 1500 | 850 | 3-phase |
Full specifications
| Chamber volume | 4000 l |
| Chamber volume | 4000 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Circulation mfr | 6400 |
| Heating mfr | 60 |
| Inner dimensions (W × D × H) mfr | 1500 × 2200 × 1200 mm |
| Outer dimensions (W × D × H) mfr | 2515 × 3350 × 1870 mm |
| Max temperature | 450 °C |
| Max temperature | 450 °C |
Description
Construction and series positioning
- The NA 4000/45 is the 4000-litre member of the NA forced-convection chamber furnace series; sibling models NA 1500/45 and N 1500/85HA offer smaller chambers (1500 l class) and, for the N 1500/85HA, a higher temperature class.
- Chamber dimensions of 1500 × 2200 × 1200 mm (W × D × H) and outer dimensions of 2515 × 3350 × 1870 mm define the footprint and load envelope; the 450 °C maximum temperature places it in the mid-temperature range of the series.
- Electrical supply is 3-phase; no voltage or power rating is stated in the verified facts, so connection data must be confirmed against the nameplate.
Behavior and media
- Forced circulation is specified at a value of 6400 (unit not stated in the source) and heating at 60 (unit not stated); these figures are recorded as factory data without further qualification.
- No digitized curve points are available, so heat-up rate, uniformity tolerance and recovery behavior under load cannot be quantified from the supplied facts.
Control and operation
- The attached controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process data storage and AMS2750F instrumentation types; it does not print model-specific settings for the NA 4000/45.
- No installation, connection or operating instructions specific to this furnace model are present in the supplied document digests.
Integration & Operating Notes
The verified facts state only '3-phase' for the electrical connection. The actual operating voltage, full-load current and recommended upstream protection are not given, so the site electrical design must be based on the unit nameplate and Nabertherm connection documentation rather than on this card.
The maximum temperature is 450 °C. Operating above this limit is outside the verified specification and may damage the circulation system, heating elements or chamber insulation; the controller setpoint and over-temperature protection should be configured so that 450 °C cannot be exceeded in normal operation.
The controller digest describes the 500 series and MyNabertherm app, including process data storage and AMS2750F instrumentation types, but contains no furnace-model-specific parameters. Control configuration and any recorder or instrumentation options must be selected from the controller documentation and confirmed for the NA 4000/45.
Selection & Integration Q&A
Choose the NA 4000/45 when the load requires the 4000-litre chamber (1500 × 2200 × 1200 mm) at up to 450 °C. The NA 1500/45 offers a smaller 1500-litre chamber at the same temperature class; the N 1500/85HA belongs to a higher temperature class (85 in the model code) and should be selected when 450 °C is insufficient.
The verified facts specify only a 3-phase connection. Voltage, full-load current and protective device ratings are not stated, so the supply and upstream protection must be sized from the unit nameplate and Nabertherm connection documentation before installation.
The outer envelope is 2515 × 3350 × 1870 mm. The supplied documents do not state required clearances, floor loading or ambient temperature limits for this model; these must be taken from Nabertherm installation instructions, and the site layout should reserve access for door swing and loading.
The supplied document digests contain no maintenance schedule or consumables list for the NA 4000/45. Controller options such as the 500 series or MyNabertherm app and any recorder or AMS2750F instrumentation are separate selections described in the controller documentation, not included in the base furnace facts.