Nabertherm NA 500/85
Nabertherm ·Made in Germany · In Active Production

Nabertherm NA 500/85

Nabertherm NA 500/85 — Furnaces Protective Gas Boxes.

The NA 500/85 is a forced-convection chamber furnace with a 500 l chamber (750 × 1000 × 750 mm) rated to 850 °C, electrically heated and connected via 3-phase supply. Within the NA series it is the 500-litre, 850 °C modification, distinguished from the NA 500/45 by its higher maximum temperature and from the NA 250/85 by its larger chamber. It serves as a batch heat-treatment unit for processes requiring uniform forced-air circulation up to 850 °C.

Full specifications

Core Performance & Functional Specifications
Chamber volume 500 l
Chamber volume 500 l
Electrical connection 3-phase
Electrical connection 3-phase
Heating mfr 30
Heat-up time3 mfr 180
Cool-down time3 from Tmax mfr 210
Inner dimensions (W × D × H) mfr 750 × 1000 × 750 mm
Outer dimensions (W × D × H) mfr 1410 × 1950 × 1960 mm
Dimensions, Weight & Mechanical Design
Weight 1150 kg
Weight 1150 kg
Operating Conditions, Environment & Protection
Max temperature 850 °C
Max temperature 850 °C

Description

Construction and series positioning

Thermal behaviour

Control and operation

Integration notes

Integration & Operating Notes

Electrical
3-phase supply required; rating must be read from nameplate

The verified facts state only that the furnace is 3-phase; no voltage, current or connected load is given. The supply, protective device and cable cross-section must therefore be sized from the unit nameplate or the manufacturer's connection diagram, not from this card, and an incorrect supply voltage risks damage to the heating and control circuits.

Factory Specification Sheet
Process Limits
Chamber load and atmosphere must stay within 850 °C rating

The maximum temperature is 850 °C; operating above it risks heater and insulation damage. The supplied facts do not define a maximum load mass or a permitted atmosphere, so charge weight, fixture material and any protective-gas or fume extraction arrangement must be agreed with the manufacturer before processing unknown loads.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the NA 500/85 rather than the NA 500/45 or the NA 250/85?

Choose the NA 500/85 when you need the 500 l chamber and processes up to 850 °C. The NA 500/45 gives the same 500 l volume at a lower maximum temperature, and the NA 250/85 gives the same 850 °C rating in a smaller 250 l chamber; pick the sibling that matches your load size and temperature together.

What electrical supply and protection does the NA 500/85 require?

The verified facts state only a 3-phase connection; no voltage, current or connected load is given. Size the supply, protective device and cable from the unit nameplate or the manufacturer's connection diagram, and confirm the site voltage before ordering.

What is included in base delivery and what must be ordered separately?

The verified facts list no accessories, cables, recorder or controller options as included. The controller documentation mentions recorder/controller options and the MyNabertherm app, but the fitted controller and any interface cables must be confirmed on the order configuration; do not assume they are part of the base unit.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF