Nabertherm NAT 30/65
Nabertherm NAT 30/65 — Laboratory ovens.
The NAT 30/65 is a tabletop forced-convection chamber furnace with a 30-litre chamber (320 × 320 × 300 mm) and a maximum working temperature of 650 °C, electrically heated from a single-phase supply. Within the NAT series it is the 650 °C modification with the smallest chamber, distinguished from the 850 °C siblings (NAT 15/85, NAT 30/85, NAT 50/85) by its lower ceiling temperature. It is intended for uniform low-to-medium temperature heat treatment of small batches in laboratory and process environments.
Full specifications
| Chamber volume | 30 l |
| Chamber volume | 30 l |
| Chamber volume | 30 l |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Heating mfr | 3,0 |
| Heat-up time3 mfr | 80 |
| Inner dimensions (W × D × H) mfr | 320 × 320 × 300 mm |
| Outer dimensions (W × D × H) mfr | 810 × 620 × 620 mm |
| Weight | 90 kg |
| Weight | 90 kg |
| Weight | 90 kg |
| Max temperature | 650 °C |
| Max temperature | 650 °C |
| Max temperature | 650 °C |
Description
Construction and series positioning
- Tabletop forced-convection chamber furnace, 30 l inner volume, inner chamber 320 × 320 × 300 mm, outer dimensions 810 × 620 × 620 mm, unit weight 90 kg.
- Electrically heated, single-phase connection; maximum temperature 650 °C.
- Within the NAT tabletop series this is the 650 °C variant with the smallest chamber; the sibling models NAT 15/85, NAT 30/85 and NAT 50/85 are 850 °C units, so the NAT 30/65 is selected when 650 °C is sufficient and the smaller chamber suits the load.
Thermal behaviour
- The factory data list a heating value of 3.0 and a heat-up time of 80; the unit and reference condition for these figures are not printed in the supplied facts, so they should be confirmed against the order documentation before use in a thermal budget.
- No digitized curve points were supplied for this model; temperature uniformity and control behaviour therefore depend on the controller and instrumentation options selected from the Nabertherm controller documentation.
Control and operation
- The supplied document digests cover Nabertherm's controller series 500 and the MyNabertherm app, including process data storage and temperature-uniformity instrumentation types; they do not print furnace-specific wiring or setpoints for the NAT 30/65.
- The catalog digest places the NAT/NA forced-convection chamber furnaces in the up-to-900 °C class; the NAT 30/65 is the 650 °C member of that family.
Integration & Operating Notes
The maximum temperature of this modification is 650 °C. The 850 °C siblings in the same series have a different thermal design; operating the NAT 30/65 above its rated ceiling risks damage to the heating elements and chamber insulation and invalidates any uniformity data.
Controller series 500 functions, process data storage and MyNabertherm app connectivity are described in a separate controller document and are not part of the base furnace facts. Specify the controller, instrumentation type and any recorder explicitly on the order.
Selection & Integration Q&A
Choose the NAT 30/65 when 650 °C is sufficient and a 30-litre chamber fits the load. The NAT 30/85 offers the same chamber volume at 850 °C; the NAT 15/85 is the smaller 850 °C unit. The NAT 50/85 is for larger loads at 850 °C.
A single-phase supply sized from the nameplate, plus a controller from the Nabertherm series 500 range if process data storage or app connectivity is required. The controller and any recorder are separate items; the furnace facts do not define a built-in control interface.
The supplied facts list only the furnace itself: 30-litre chamber, 650 °C maximum, single-phase connection, 90 kg. Controllers, recorders, the MyNabertherm app link and any instrumentation for temperature uniformity are documented separately and are not confirmed as part of the base delivery.