Nabertherm NE 40/WAX
Nabertherm NE 40/WAX — Compact Dewaxing Furnace Ne 40wax Investment Casting Electrically Heated.
The NE 40/WAX is a 40-litre electrically heated dewaxing furnace with a 1000 °C maximum temperature and 3.6 kW single-phase heating, built for investment casting wax removal. Its 350 × 320 × 350 mm chamber and 0.5 kg charge limit define a small-batch modification within the compact NE series, intended to melt and collect wax from ceramic shells before sintering.
Full specifications
| Chamber volume | 40 l |
| Electrical connection | 1-phase |
| Nominal power | 3.6 kW |
| Maximum collection tray capacity mfr | 0,5 |
| Inner dimensions (W × D × H) mfr | 350 × 320 × 350 mm |
| Outer dimensions (W × D × H) mfr | 710 × 690 × 800 mm |
| Weight | 130 kg |
| Maximum charge weight mfr | 0,5 |
| Max temperature | 1000 °C |
Description
Construction and series positioning
The NE 40/WAX is the smallest chamber volume (40 l) in the compact dewaxing furnace line, distinguished by a 1000 °C maximum temperature and a 3.6 kW single-phase element set. The chamber measures 350 mm wide × 320 mm deep × 350 mm high, and the outer envelope is 710 × 690 × 800 mm at 130 kg. A maximum charge weight of 0.5 kg and a collection tray capacity of 0.5 kg set this model apart from larger siblings: it is a bench-scale unit for single shell trees or small batches, not for production-scale dewaxing.
Thermal behaviour and process limits
With no digitized curve points supplied, the operating envelope is defined by the 1000 °C ceiling and the 0.5 kg charge limit. The charge limit is the governing constraint: wax runoff and shell load must stay within 0.5 kg, and the collection tray must not exceed 0.5 kg of melted wax. Exceeding either limit risks overflow or incomplete dewaxing; the furnace is not rated for continuous heavy loading.
Installation and control
Electrical connection is single-phase at 3.6 kW nominal; the supply must be sized for this load and for the furnace's control electronics. The unit is free-standing at 130 kg and requires clear access to the chamber door and collection tray for wax removal. Controller and process documentation in the attached digests covers the Nabertherm 500 series and MyNabertherm app, but no model-specific wiring or ramp tables are printed; commissioning should follow the furnace's own manual.
Integration & Operating Notes
The furnace draws 3.6 kW on a single-phase connection; the circuit, breaker and cable must be sized for this continuous load plus control electronics. Sharing the circuit with other high-draw equipment risks nuisance tripping and undervoltage during heat-up.
Both the maximum charge weight and the maximum collection tray capacity are 0.5 kg. Loading more shell or wax than this can overflow the tray, contaminate the chamber and leave wax in the insulation; weigh the charge before each cycle and empty the tray before it reaches capacity.
The attached process-control digest covers the 500 series controllers and MyNabertherm app, including data storage and recorder options, but does not print model-specific wiring or ramp programs. Configure and validate the control loop against the furnace manual before production use.
Selection & Integration Q&A
Choose the NE 40/WAX for single small shell trees or batches within its 0.5 kg charge and 0.5 kg tray limits in a 40 l chamber. Larger siblings are needed once charge weight or batch count exceeds these limits; the 1000 °C ceiling suits standard wax burnout.
A dedicated single-phase circuit sized for 3.6 kW, plus a controller from the Nabertherm 500 series or MyNabertherm app if automated ramps are needed. The collection tray is integral; no external wax drain or pump is specified in the supplied facts.
The collection tray must be emptied before reaching 0.5 kg of wax, and the chamber kept free of wax residue. Controllers, recorders and the MyNabertherm app are separate options, not part of the base furnace; no cables or spares are listed in the supplied facts.