Nabertherm NR(A) 100/..
Nabertherm ·Made in Germany · In Active Production

Nabertherm NR(A) 100/..

Nabertherm NR(A) 100/.. — Hot Wall Retort Furnaces.

The NR(A) 100/.. is a hot-wall retort furnace from Nabertherm's NR(A) series, with a 100-litre useful volume and a work space of 450 × 500 × 450 mm. It sits between the NR(A) 40/.. and NR(A) 160/.. siblings, intended for processes requiring a heated retort wall up to 1100 °C.

Full specifications

Core Performance & Functional Specifications
Work space dimensions in mm mfr 450
Useful volume mfr 100
Connected1 mfr 64
Outer dimensions (W × D × H) mfr 14002 × 2000 × 2100 mm

Description

Construction and series positioning

Behavior and process media

Control and operation

Integration & Operating Notes

Process Limits
Do not exceed 1100 °C retort temperature

The series is specified for a maximum of 1100 °C. Operating above this limit risks damage to the retort and heating system; the actual setpoint limit for the NR(A) 100/.. must be confirmed in the furnace manual before first run.

Series specification (Hot-Wall Retort Furnaces up to 1100 °C
Control & I/O
Controller platform supports 500-series and MyNabertherm app

The controller documentation describes the 500-series controllers and the MyNabertherm app, including process data storage and AMS2750F instrumentation types. These are platform capabilities; the controller actually supplied with the NR(A) 100/.. must be confirmed on the order.

Prozesssteuerung englisch (controller documentation
Maintenance
No model-specific maintenance intervals are documented

The supplied document digests contain no maintenance schedule, error codes or service intervals for the NR(A) 100/..; the furnace manual must be consulted for retort inspection and replacement criteria.

Supplied document digests (no model-specific maintenance section

Selection & Integration Q&A

When should I choose the NR(A) 100/.. rather than the NR(A) 40/.. or NR(A) 160/..?

Choose the 100/.. when the workload fits the 450 × 500 × 450 mm work space and 100-litre useful volume. The 40/.. is smaller; the 160/.. offers more volume. No performance data beyond size is available to differentiate them.

What adjacent equipment must be specified with the NR(A) 100/..?

The supplied facts do not define the electrical supply, controller model or retort connections for this unit. The controller platform documentation covers 500-series controllers and the MyNabertherm app, but the actual configuration must be confirmed against the furnace manual and order.

What are the mounting and duty-cycle limits for the NR(A) 100/..?

No mounting clearances, ambient conditions or duty-cycle limits are given in the supplied facts. The outer dimension entry (14002 × 2000 × 2100 mm) is inconsistent and cannot be used for layout; obtain certified dimensions from Nabertherm.

What maintenance and consumables are required, and what is not included in base delivery?

The supplied documents list no maintenance intervals, spare parts or consumables for this model, and do not define base-delivery scope. Retort condition and controller options must be confirmed with Nabertherm; no accessories are assumed included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF