Nabertherm RHTH 80/300/..
Nabertherm RHTH 80/300/.. — Tube furnaces.
The RHTH 80/300/.. is a horizontally or vertically operable high-temperature tube furnace accepting tubes up to 80 mm outer diameter, with a 300 mm heated length and 1700 °C maximum temperature. Its 9.4 kW three-phase connection and 90 kg frame distinguish it from the larger RHTH 120/600/.. sibling. It serves controlled-atmosphere or air processing of small-diameter tubular workloads requiring a defined 100–150 mm constant-temperature zone.
Nabertherm RHTH Series — Model Comparison & Selection
| Model | Max temperature, °C | Weight, kg | Electrical connection |
|---|---|---|---|
| RHTH 80/300/.. Current | 1700 | 90 | 3-phase4 |
| RHTH 120/600/.. | 1800 | 110 | 3-phase4 |
Full specifications
| Electrical connection | 3-phase4 |
| Nominal power | 9.4 kW |
| Max. outer tube Ø mfr | 80 |
| Outer dimensions (W × D × H) mfr | 550 × 640 mm |
| Weight | 90 kg |
| Heated length mfr | 300 |
| Tube length mfr | 530 |
| Max temperature | 1700 °C |
Description
Construction and series positioning
- The RHTH 80/300/.. is the smaller tube-geometry member of the RHTH high-temperature series; the sibling RHTH 120/600/.. accepts a larger tube and longer heated section.
- Maximum outer tube diameter is 80 mm, heated length 300 mm, and overall tube length 530 mm, leaving approximately 115 mm of cold tube at each end for seals and gas connections.
- The 550 × 640 mm outer footprint and 90 kg mass indicate a benchtop or floor-standing frame; the furnace is specified for horizontal or vertical operation, so the mounting orientation must be decided before installation.
- The 9.4 kW nominal power at 3-phase/4-wire connection places this model in a fixed-installation electrical class rather than a plug-in laboratory appliance.
Thermal behavior and working zone
- Maximum temperature is 1700 °C. The constant-temperature zone is 100 mm long at the higher uniformity grade and 150 mm at the lower grade; the 300 mm heated length therefore includes transition zones outside the defined uniform section.
- No digitized heating or cooling curves are supplied for this model, so ramp rates must be established empirically or taken from the furnace's own controller documentation rather than from this card.
- The 80 mm tube limit and 300 mm heated length constrain workload diameter and axial placement: samples must sit within the 100–150 mm uniform band to be at setpoint.
Control, connection and operation
- The attached controller digest covers the Nabertherm 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types; it does not print model-specific wiring for the RHTH 80/300/.., so the controller variant must be confirmed at order.
- The other attached digests (fiber-optics glass, foundry, dental) cover unrelated product lines and contain no RHTH-specific installation facts; they should not be used to infer this furnace's connections or accessories.
- Because the furnace can be operated vertically, tube retention and gas-seal hardware must be selected for the chosen orientation; the base delivery scope is not documented in the supplied facts.
Integration & Operating Notes
The 300 mm heated length does not mean 300 mm of uniform temperature: the constant-temperature zone is 100 mm or 150 mm depending on the uniformity grade. Samples placed outside that band will see axial gradients, so the effective working length for qualified processes is the shorter uniform figure.
The furnace is built around a maximum outer tube diameter of 80 mm. Larger tubes will not fit the insulation and heating arrangement, and the 530 mm tube length must also be respected so that the tube ends clear the furnace body for seals and gas connections.
Selection & Integration Q&A
Pick the 80/300 when tube outer diameter stays at or below 80 mm and the qualified uniform zone of 100–150 mm is sufficient. The 120/600 sibling is the choice for larger tubes or longer uniform sections; it is a different frame, not an upgrade kit.
A 3-phase/4-wire supply rated for the 9.4 kW nominal power, with a dedicated protected circuit and local isolator. Single-phase bench outlets are not suitable; the installer should size conductors and breakers for the full connected load.
The series permits horizontal or vertical operation, but the 90 kg mass and 550 × 640 mm footprint must be supported, and the tube seals and gas connections must be configured for the chosen orientation. Hood placement also depends on local exhaust and heat-dissipation requirements not stated in the supplied facts.
The supplied facts do not list a process tube, end seals, gas fittings or thermocouple feedthroughs in base delivery. Confirm the delivery scope with the order and separately procure an 80 mm max tube of 530 mm length plus seals suited to the gas or vacuum used.