Nabertherm RT 50/250/11
Nabertherm RT 50/250/11 — Tube furnaces.
The RT 50/250/11 is a horizontal/vertical tube furnace with a 50 mm inner tube diameter and a 250 mm heated length, rated to 1100 °C on a 1-phase supply. It is the 1100 °C modification of the RT 50/250 series, distinguished from the RT 50/250/13 sibling by its lower maximum temperature. It is intended for laboratory thermal processing of small-diameter tubes where 1100 °C is sufficient.
Nabertherm RT Series — Model Comparison & Selection
| Model | Max temperature, °C | Electrical connection | Weight, kg |
|---|---|---|---|
| RT 50/250/11 Current | 1100 | 1-phase | 25 |
| RT 50/250/13 | 1300 | 1-phase | 25 |
Full specifications
| Electrical connection | 1-phase |
| Inner tube Ø mfr | 50 |
| Heated mfr | 250 |
| Connected mfr | 2 |
| Outer dimensions (W × D × H) mfr | 350 × 380 × 740 mm |
| Weight | 25 kg |
| Length constant mfr | 80 |
| Tube length mfr | 360 |
| Max temperature | 1100 °C |
Description
Construction and series positioning
- The RT 50/250/11 is built around a 50 mm inner-diameter process tube with a 250 mm heated zone, an 80 mm constant-temperature length, and a 360 mm overall tube length.
- The furnace is mounted on a stand for horizontal or vertical operation, with outer dimensions of 350 × 380 × 740 mm and a weight of 25 kg.
- Within the RT 50/250 series, this model is the 1100 °C variant; the sibling RT 50/250/13 reaches 1300 °C. The /11 is selected when the process maximum stays at or below 1100 °C and the higher-temperature /13 is not required.
Behavior and process envelope
- Maximum working temperature is 1100 °C. The 80 mm constant-temperature length defines the zone over which the 250 mm heated length can be expected to hold uniform temperature; work should be centered in this zone.
- No digitized curve points are available for this model, so heat-up and cool-down behavior cannot be characterized from the supplied facts.
Installation, connection and control
- Electrical connection is 1-phase; connected load is listed as 2 (unit not stated in the supplied facts).
- The attached document digests cover Nabertherm controller series 500 and the MyNabertherm app, process-data storage, and AMS2750F instrumentation types, but they do not print model-specific wiring, sensor type, or control-loop details for the RT 50/250/11. Controller configuration must therefore be confirmed against the model-specific manual before commissioning.
Integration & Operating Notes
The 1100 °C rating is the ceiling for this modification. The sibling RT 50/250/13 exists for processes requiring up to 1300 °C; running the /11 above its rating risks tube and insulation damage and invalidates results.
The furnace is supplied on a stand for both horizontal and vertical operation. The chosen orientation determines how the 360 mm tube is supported and how the 80 mm constant-temperature zone is positioned relative to the workload; plan the bench or floor space around the 350 × 380 × 740 mm envelope and 25 kg mass.
The unit is a 1-phase furnace with a connected load listed as 2 (unit not stated in the supplied facts). The supply circuit, protection and cable cross-section must be sized against the model-specific nameplate and manual, not against generic series data.
Selection & Integration Q&A
Pick the /11 when the process maximum stays at or below 1100 °C; the tube, heated length (250 mm) and 50 mm bore are the same. Choose the /13 only if the process genuinely needs up to 1300 °C, since the /11 cannot be run above its 1100 °C rating.
A 1-phase supply sized to the connected load (listed as 2, unit not stated) and a compatible Nabertherm controller. The supplied controller digest covers series 500 and MyNabertherm but gives no model-specific sensor or interface assignment, so confirm thermocouple type and wiring in the model manual.
Yes — the stand supports horizontal and vertical operation. In either orientation the 80 mm constant-temperature length inside the 250 mm heated zone is where the workload should sit; the 360 mm tube length sets how far the process tube extends beyond the heated section.
The supplied facts list only the furnace on its stand with the 50 mm tube geometry; no controller, thermocouple, process tube accessories or cables are confirmed as included. Controller options (series 500, MyNabertherm) and instrumentation per AMS2750F must be specified separately.