Nabertherm S 73/HS
Nabertherm S 73/HS — Special application furnaces.
The S 73/HS is a 73-litre, 3-phase chamber furnace rated to 1300 °C, built for fire-assay and cupellation duty in the Nabertherm special-application line. Its 530 × 380 × 360 mm chamber and 890 kg frame distinguish it from the smaller N 4/13 CUP sibling. It serves as the high-throughput fusion and cupellation stage in analytical laboratories.
Full specifications
| Chamber volume | 73 l |
| Electrical connection | 3-phase |
| Connected mfr | 26 |
| Inner dimensions (W × D × H) mfr | 530 × 380 × 360 mm |
| Outer dimensions (W × D × H) mfr | 1050 × 1530 × 900 mm |
| Weight | 890 kg |
| Max temperature | 1300 °C |
Description
Construction and series positioning
- Chamber volume 73 l with inner dimensions 530 × 380 × 360 mm (W × D × H); outer envelope 1050 × 1530 × 900 mm at 890 kg.
- 3-phase electrical connection; maximum working temperature 1300 °C.
- Within the fire-assay/cupellation series, this is the larger chamber modification; the sibling N 4/13 CUP is the compact alternative for smaller batch sizes.
Thermal behaviour
- No digitized curve points or cooling-rate data are available for this model; the 1300 °C ceiling is the only verified thermal limit. Do not assume ramp rates or uniformity figures from other series documents.
Control and operation
- The attached controller documentation covers the Nabertherm 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but prints no model-specific wiring or setpoint tables for the S 73/HS. Controller configuration must therefore be confirmed against the order-specific wiring diagram.
- No installation, connection or maintenance procedures specific to this model appear in the supplied digests; the foundry, dental and fiber-optics documents cover other product lines and are not applicable.
Integration & Operating Notes
The 1300 °C maximum is the only verified thermal limit for this model; operating above it risks heating-element and insulation damage. No ramp or uniformity data are supplied, so process recipes must be validated on the installed unit.
The controller digest describes 500-series functions, process-data storage and AMS2750F instrumentation types but prints no S 73/HS-specific parameters; the delivered controller variant and any recorder option must be confirmed on the order confirmation.
Selection & Integration Q&A
Pick the S 73/HS when the 73-litre chamber (530 × 380 × 360 mm) and 1300 °C ceiling match your batch size and 3-phase power is available. The N 4/13 CUP is the compact alternative; no further comparative data are verified.
The unit is 3-phase; the listed 'Connected' value of 26 has no unit, so the kW rating must be taken from the nameplate. Size the feeder, disconnect and overcurrent protection from that nameplate value, not from the ambiguous table entry.
The supplied digests contain no S 73/HS-specific maintenance schedule, error codes or accessory list; controller and recorder options are described only generically. Service intervals and any cables or consumables must be confirmed with Nabertherm for the ordered configuration.