Nabertherm SRO 170/1000/11
Nabertherm SRO 170/1000/11 — Special application furnaces.
Electrically heated vertical cleaning furnace for riser tubes, model SRO 170/1000/11, with a 1000 mm heated length and 90 mm outer tube diameter, rated to 1100 °C on a 3-phase supply. Its 12.0 kW heating capacity and 590 × 640 × 1700 mm cabinet support stand-alone burnout of foundry riser tubes.
Full specifications
| Electrical connection | 3-phase |
| Outer tube-Ø mfr | 90 |
| Heated mfr | 1000 |
| Heating mfr | 12,0 |
| Outer dimensions (W × D × H) mfr | 590 × 640 × 1700 mm |
| Max temperature | 1100 °C |
Description
Construction and series positioning
- The SRO 170/1000/11 is a vertical, electrically heated cleaning furnace configured around a 90 mm outer tube diameter and a 1000 mm heated length; the 1700 mm overall height accommodates the tube chamber and connections.
- Heating capacity is 12.0 kW from a 3-phase electrical connection, with a maximum working temperature of 1100 °C.
- No sibling models are listed for this series, so the 1000 mm heated length and 90 mm tube diameter define this modification's position: it is sized for riser tubes within that diameter and heated length.
Behavior and process role
- The furnace is intended for thermal cleaning of riser tubes; the 1100 °C ceiling covers burnout of organic residues without exceeding the chamber rating.
- No digitized curve points or atmosphere data are supplied, so heat-up rates, uniformity and atmosphere compatibility cannot be stated for this model.
Control and operation
- The attached controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process data storage and AMS2750F instrumentation types; it does not print model-specific settings for the SRO 170/1000/11.
- No installation, connection or operating instructions specific to this furnace are present in the supplied document digests.
Integration & Operating Notes
The furnace is a 3-phase unit with 12.0 kW of heating capacity; the site supply, protective devices and cable cross-section must be selected for that load. No voltage or current value is stated in the verified facts, so the nameplate must be consulted before connection.
The maximum temperature is 1100 °C. Controller setpoints and over-temperature protection should be configured so the chamber cannot be driven above this value, since no margin or short-term excursion rating is given.
Process control, data storage and AMS2750F instrumentation types are described in the controller documentation for the 500 series and MyNabertherm app. The actual controller fitted to this unit and its interface options are not stated in the verified facts and must be confirmed at order.
Selection & Integration Q&A
Choose it when riser tubes fit a 90 mm outer diameter and a 1000 mm heated length and cleaning temperatures stay at or below 1100 °C. No sibling SRO models are listed, so other tube diameters or heated lengths require a different series or a custom configuration.
The unit is 3-phase with 12.0 kW heating capacity. Voltage and current are not given in the verified data, so size the feeder, disconnect and overcurrent protection from the nameplate; do not assume a voltage from the model code.
The verified facts list no consumables, spare parts or cables, and the document digests contain no maintenance schedule for this model. Service intervals, thermocouple replacement and any recorder or controller options must be confirmed with Nabertherm; nothing beyond the furnace itself should be assumed included.