Nabertherm SRO 170/1000/11
Nabertherm ·Made in Germany · In Active Production

Nabertherm SRO 170/1000/11

Nabertherm SRO 170/1000/11 — Special application furnaces.

Electrically heated vertical cleaning furnace for riser tubes, model SRO 170/1000/11, with a 1000 mm heated length and 90 mm outer tube diameter, rated to 1100 °C on a 3-phase supply. Its 12.0 kW heating capacity and 590 × 640 × 1700 mm cabinet support stand-alone burnout of foundry riser tubes.

Full specifications

Core Performance & Functional Specifications
Electrical connection 3-phase
Outer tube-Ø mfr 90
Heated mfr 1000
Heating mfr 12,0
Outer dimensions (W × D × H) mfr 590 × 640 × 1700 mm
Operating Conditions, Environment & Protection
Max temperature 1100 °C

Description

Construction and series positioning

Behavior and process role

Control and operation

Integration & Operating Notes

Electrical
3-phase supply must be sized for the 12.0 kW heating load

The furnace is a 3-phase unit with 12.0 kW of heating capacity; the site supply, protective devices and cable cross-section must be selected for that load. No voltage or current value is stated in the verified facts, so the nameplate must be consulted before connection.

Factory Specification Sheet
Process Limits
Chamber temperature must not exceed 1100 °C

The maximum temperature is 1100 °C. Controller setpoints and over-temperature protection should be configured so the chamber cannot be driven above this value, since no margin or short-term excursion rating is given.

Factory Specification Sheet
Control & I/O
Controller functions are documented separately from the furnace

Process control, data storage and AMS2750F instrumentation types are described in the controller documentation for the 500 series and MyNabertherm app. The actual controller fitted to this unit and its interface options are not stated in the verified facts and must be confirmed at order.

Prozesssteuerung englisch

Selection & Integration Q&A

When should I choose the SRO 170/1000/11 rather than another cleaning furnace variant?

Choose it when riser tubes fit a 90 mm outer diameter and a 1000 mm heated length and cleaning temperatures stay at or below 1100 °C. No sibling SRO models are listed, so other tube diameters or heated lengths require a different series or a custom configuration.

What supply and protective equipment does the 3-phase connection require?

The unit is 3-phase with 12.0 kW heating capacity. Voltage and current are not given in the verified data, so size the feeder, disconnect and overcurrent protection from the nameplate; do not assume a voltage from the model code.

What maintenance and accessories are not included in the base delivery?

The verified facts list no consumables, spare parts or cables, and the document digests contain no maintenance schedule for this model. Service intervals, thermocouple replacement and any recorder or controller options must be confirmed with Nabertherm; nothing beyond the furnace itself should be assumed included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF