Nabertherm TC 80/14
Nabertherm ·Made in Germany · In Active Production

Nabertherm TC 80/14

Nabertherm TC 80/14 — Bale Out Furnaces Electrically Heated Or Gas Fired.

The TC 80/14 is a SiC-rod-heated bale-out furnace with a BU 200 crucible and 650 kg melt capacity, rated to 1450 °C. Its 94 kW nominal power supports a melting performance of 1802 kg (likely per 24 h, per foundry catalog convention). It is intended for holding and melting non-ferrous alloys for manual or transfer-ladle casting in foundries.

Full specifications

Core Performance & Functional Specifications
Heating power 48 watt
Nominal power 94 kW
Crucible mfr BU 200
Capacityin kg mfr 650
Melting performance3in kg mfr 1802
Outer dimensions (W × D × H) mfr 1360 × 1350 × 1080 mm
Dimensions, Weight & Mechanical Design
Weight 1050 kg
Operating Conditions, Environment & Protection
Max temperature 1450 °C

Description

Construction and series positioning

Thermal behavior and limits

Control and operation

Integration & Operating Notes

Process Limits
Do not exceed 1450 °C furnace temperature

The SiC rod elements and crucible are rated to a maximum of 1450 °C. Operating above this ceiling risks element degradation and crucible failure; the setpoint must be interlocked or procedure-limited to this value.

Factory Specification Sheet
Electrical
Confirm 94 kW supply and protection before installation

The nominal power of 94 kW requires a dedicated supply sized for the furnace's actual voltage and phase configuration, which is not stated in the verified data. The electrical design must be taken from the model-specific nameplate and manual, not from the catalog overview.

Factory Specification Sheet
Process Limits
Match crucible and charge to BU 200 capacity

The furnace is supplied with a BU 200 crucible and a stated capacity of 650 kg. Charging above the crucible's rated volume or weight, or using a non-matching crucible, changes the thermal profile and can damage the crucible or elements.

Factory Specification Sheet
Control & I/O
Controller and recorder are separate selection items

The controller digest describes 500-series controllers and MyNabertherm app functions, including process-data storage and AMS2750F instrumentation types, but does not fix a controller for this model. Specify the controller, thermocouples, and any recorder as separate line items.

Prozesssteuerung englisch
Maintenance
SiC rod elements age and need periodic replacement

SiC rod heating elements increase in resistance with age, so the furnace's power delivery changes over time. Plan for element resistance checks and replacement as a consumable item; the verified data gives no interval, so the model manual must define it.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the TC 80/14 rather than another TC bale-out furnace?

Choose the TC 80/14 when the melt batch is built around a BU 200 crucible and about 650 kg of capacity at up to 1450 °C. No sibling TC models are listed in the verified data, so compare crucible size and capacity against the full TC range before ordering.

What supply and control hardware must be provided alongside the furnace?

The furnace has a 94 kW nominal power rating, but the verified data does not state voltage or phase. Size the supply and protection from the model nameplate, and specify a 500-series controller or equivalent plus thermocouples separately, since the controller is not fixed in the verified data.

What maintenance and consumables are not included in the base delivery?

SiC rod elements are consumable and age with use; the verified data gives no replacement interval, so the model manual must define it. Controllers, recorders, thermocouples, and the BU 200 crucible's spare units are separate items, not part of the base furnace delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF