Nabertherm WK 4500
Nabertherm WK 4500 — Heating Cabinets Chamber Ovens.
The WK 4500 is an electrically heated heating cabinet with a 4500 l chamber, rated for a maximum temperature of 150 °C and a nominal power of 21 kW. Its 1500 × 2000 mm inner footprint distinguishes it within the WK series, which also includes the WK 10001 and WK 12000. It is intended for large-volume, low-temperature thermal processing such as drying, preheating, or tempering in industrial workflows.
Full specifications
| Chamber volume | 4500 l |
| Heating power | 18 watt |
| Nominal power | 21 kW |
| Inner dimensions (W × D × H) mfr | 1500 × 2000 mm |
| Outer dimensions (W × D × H) mfr | 1980 × 3110 × 2500 mm |
| Max temperature | 150 °C |
Description
Construction and series positioning
- The WK 4500 is a chamber oven of the WK heating cabinet line, built for a 4500 l working volume with inner dimensions of 1500 × 2000 mm (W × D) and outer dimensions of 1980 × 3110 × 2500 mm (W × D × H).
- Within the series, the WK 4500 is the mid-size unit relative to the WK 10001 and WK 12000, which offer larger chamber volumes. Selection among these siblings should be driven by batch footprint and volume rather than by temperature class, since all share the 150 °C ceiling.
- The cabinet is electrically heated with a nominal power of 21 kW; the matched heating-power entry of 18 W is inconsistent with the 21 kW nominal rating and is therefore not used as a performance figure.
Thermal behavior and operating envelope
- The maximum temperature is 150 °C, which places the WK 4500 in the low-temperature drying and tempering segment rather than in the chamber-furnace range (KTR up to 260 °C, NAT/NA up to 900 °C per the fiber-optics catalog digest).
- No digitized curve points are available for this model, so heat-up rate, uniformity, and recovery behavior cannot be quantified from the supplied facts; these must be obtained from the factory data sheet or commissioning measurements.
- Because the cabinet is not an LS variant (EN 1539 safety technology applies to TR and KTR models per the catalog digest), solvent-load processes requiring LS configuration are outside this model's documented scope.
Control, installation, and operation
- The document digests reference the Nabertherm controller series 500 and the MyNabertherm app for process data storage, temperature uniformity, and AMS2750F instrumentation types, but they do not print model-specific wiring or ordering codes for the WK 4500.
- No WK-specific installation, connection, or control details are present in the supplied digests; the engineer should treat controller selection, sensor type, and recorder options as project-specific and confirm them against the WK 4500 order documentation.
- The outer dimensions (1980 × 3110 × 2500 mm) define the transport and installation envelope; door swing, service access, and exhaust routing must be planned around this footprint.
Integration & Operating Notes
The maximum temperature is 150 °C. Exceeding it risks damage to the charge, the insulation, and the heating elements, and invalidates any documented process. Temperature setpoints and over-temperature protection should be configured with this ceiling in mind.
The catalog digest states that LS variants per EN 1539 apply to TR and KTR models, not to the WK heating cabinets. Processes involving solvent loads that require LS configuration should not be assigned to the WK 4500 without explicit factory confirmation.
Selection & Integration Q&A
Choose the WK 4500 when the batch fits a 4500 l chamber with a 1500 × 2000 mm inner footprint and the process stays at or below 150 °C. The WK 10001 and WK 12000 offer larger volumes; move to them only when the charge exceeds the WK 4500 footprint, since all share the same 150 °C ceiling.
The supply, protection, and cable cross-section must be sized for the full 21 kW nominal rating. The matched heating-power entry of 18 W contradicts the 21 kW nominal figure and should not be used for dimensioning; confirm the final electrical data against the WK 4500 order documentation.
The supplied digests do not define a base controller, sensor, or recorder for the WK 4500; they only describe series 500 and MyNabertherm app functions and AMS2750F instrumentation types in general. Controller, sensor, and recorder selection must be confirmed against the WK 4500 order documentation.