Nabertherm WK 4500

Nabertherm WK 4500 — Heating Cabinets Chamber Ovens.

The WK 4500 is an electrically heated heating cabinet with a 4500 l chamber, rated for a maximum temperature of 150 °C and a nominal power of 21 kW. Its 1500 × 2000 mm inner footprint distinguishes it within the WK series, which also includes the WK 10001 and WK 12000. It is intended for large-volume, low-temperature thermal processing such as drying, preheating, or tempering in industrial workflows.

Full specifications

Core Performance & Functional Specifications
Chamber volume 4500 l
Heating power 18 watt
Nominal power 21 kW
Inner dimensions (W × D × H) mfr 1500 × 2000 mm
Outer dimensions (W × D × H) mfr 1980 × 3110 × 2500 mm
Operating Conditions, Environment & Protection
Max temperature 150 °C

Description

Construction and series positioning

Thermal behavior and operating envelope

Control, installation, and operation

Integration & Operating Notes

Process Limits
Chamber temperature must not exceed 150 °C

The maximum temperature is 150 °C. Exceeding it risks damage to the charge, the insulation, and the heating elements, and invalidates any documented process. Temperature setpoints and over-temperature protection should be configured with this ceiling in mind.

Factory Specification Sheet
Process Limits
LS safety technology is not part of this model's documented scope

The catalog digest states that LS variants per EN 1539 apply to TR and KTR models, not to the WK heating cabinets. Processes involving solvent loads that require LS configuration should not be assigned to the WK 4500 without explicit factory confirmation.

Fiber optics glass english 0

Selection & Integration Q&A

When should I choose the WK 4500 rather than the WK 10001 or WK 12000?

Choose the WK 4500 when the batch fits a 4500 l chamber with a 1500 × 2000 mm inner footprint and the process stays at or below 150 °C. The WK 10001 and WK 12000 offer larger volumes; move to them only when the charge exceeds the WK 4500 footprint, since all share the same 150 °C ceiling.

What supply and protection must be provided for the 21 kW nominal load?

The supply, protection, and cable cross-section must be sized for the full 21 kW nominal rating. The matched heating-power entry of 18 W contradicts the 21 kW nominal figure and should not be used for dimensioning; confirm the final electrical data against the WK 4500 order documentation.

Which controller, sensor, and recorder options are included in the base delivery?

The supplied digests do not define a base controller, sensor, or recorder for the WK 4500; they only describe series 500 and MyNabertherm app functions and AMS2750F instrumentation types in general. Controller, sensor, and recorder selection must be confirmed against the WK 4500 order documentation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF