Nabertherm WS 1000/10
Nabertherm WS 1000/10 — Prozesse Unter Luft.
Electrically heated bogie hearth furnace with a 1000 l chamber (800 × 1600 × 800 mm) rated to 1000 °C and a maximum charging weight of 840 kg. The 60 kW heating system runs on a 3-phase supply. Its 800 mm chamber width and 1600 mm depth suit long or bulky loads that are charged on a rail-mounted bogie hearth.
Full specifications
| Chamber volume | 1000 l |
| Electrical connection | 3-phase |
| Heating mfr | 60 |
| Inner dimensions (W × D × H) mfr | 800 × 1600 × 800 mm |
| Outer dimensions (W × D × H) mfr | 1720 × 2550 × 1860 mm |
| Max. charging weight mfr | 840 |
| Max temperature | 1000 °C |
Description
Construction and positioning
- The WS 1000/10 is a bogie hearth furnace: the load sits on a hearth car that travels out of the chamber for charging and back in for firing, so heavy or awkward parts are handled outside the heated zone.
- Chamber geometry is 800 mm wide × 1600 mm deep × 800 mm high (1000 l); the outer envelope is 1720 × 2550 × 1860 mm, leaving room for the hearth travel and door mechanism.
- Heating is electric, 60 kW, on a 3-phase connection; maximum temperature is 1000 °C.
- No sibling models are listed for this series, so the card describes this modification only.
Load behavior
- The maximum charging weight is 840 kg, which is the governing limit for hearth loading; it must be respected independently of the 1000 l volume, since dense loads reach the weight limit before filling the chamber.
- No digitized curves are available for this model, so heat-up and uniformity behavior cannot be quantified here; the 1000 °C ceiling is the only verified thermal rating.
Control and operation
- The attached controller documentation covers the Nabertherm 500 series and the MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but it prints no furnace-specific settings for the WS 1000/10.
- The other attached digests (fiber-optics glass, foundry, dental) cover different product lines and contain no WS 1000/10 data; they are not used for this card.
Integration & Operating Notes
The furnace is a 3-phase unit with 60 kW of heating; the site supply, cable cross-section and protection must be engineered for that load, and the connection hardware is not part of the base delivery. Confirm the plant's available three-phase capacity before siting the furnace.
The 840 kg maximum charging weight is a structural limit of the hearth and its drive. Dense loads can reach it well before the 1000 l chamber is full, so each charge must be weighed or estimated; exceeding it risks hearth deformation and rail damage.
The maximum temperature of 1000 °C is the upper bound for every program; processes requiring higher temperatures need a different furnace class. Work below the ceiling also extends heating-element life, since operation near the limit accelerates wear.
The controller documentation covers the 500 series and MyNabertherm app with process-data storage and AMS2750F instrumentation types, but it does not define the WS 1000/10 delivery scope. Specify the controller, recorder and instrumentation type explicitly at order time.
Selection & Integration Q&A
Pick it when loads fit within 800 × 1600 × 800 mm and stay under 840 kg at up to 1000 °C. Its 1600 mm depth suits long parts; larger or heavier charges need a bigger bogie hearth model, which is not listed in the verified data for this series.
A 3-phase supply sized for the 60 kW heating load, with cable and protection chosen accordingly. Connection hardware is not included in the base delivery, and the controller documentation gives no furnace-specific wiring data, so the electrical design must be confirmed at order.
The verified data lists no maintenance intervals, consumables or included accessories. Controller and recorder options from the 500 series documentation are separate items; heating elements and hearth drive parts should be planned as service spares, with intervals set by the supplier.