Pfeiffer Vacuum MVP 003-2 DC
Pfeiffer Vacuum ·Made in Germany · In Active Production

Pfeiffer Vacuum MVP 003-2 DC

Pfeiffer Vacuum MVP 003-2 DC — Diaphragm / Membrane Vacuum Pumps with Pumping speed 0.25 m³/h, Ultimate pressure 7 mbar.

The MVP 003-2 DC is an oil-free, two-head/two-stage diaphragm vacuum pump with 24 V DC drive, 0.25 m³/h pumping speed and 7.0 hPa ultimate pressure. As the smallest entry of the MVP 003-015 series it has no I/O interface and fixed 3000 min⁻¹ speed, serving compact OEM and benchtop evacuation or backing duty.

Pumping speed
0.25 m³/h
Ultimate pressure
7 mbar

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.25 m3/h
Ultimate pressure 7.0 hPa
Rotational speed 3000.0 min-1
Gas ballast mfr Yes
Nominal rotation speed mfr 3000.0 min-1
Intake pressure max. mfr 1000.0 hPa
Exhaust pressure max. mfr 1300.0 hPa
Dimensions, Weight & Mechanical Design
Weight 0.7 kg
Dimensions (L x W x H) mfr 116.0 x 116 x 62 mm
Electrical, Power & Drive Specifications
Power supply 24.0 V DC
Current max. mfr 0.5 A
Interfaces, Connections & Control
Inlet flange G 1/8"
Outlet flange G 1/8" with silencer
Operating Conditions, Environment & Protection
Noise level 48.0 dB
Operating temperature 5 - 40 °C
Cooling type Natural convection
Protection class mfr IP30

Description

Architecture and position in the series

Behavior in operation

Installation, connection and servicing

Selection & Integration Q&A

When should I choose the MVP 003-2 DC instead of the Vario or the DC Neo variants?

Choose it for simple fixed-speed duty (3000 min⁻¹) with no remote control — it has no I/O interface, unlike the Vario (0–5 V analog speed input, speed feedback) and the DC Neo (RS-485). If you need lower ultimate pressure (1.0 hPa) or higher speed (0.6 m³/h), step up to MVP 010-3 DC Neo.

What does the 24 V DC power supply need to meet?

24 V DC, max. 0.5 A, fused, with double isolation per IEC 61010-1/60950-1/62368-1. The MVP 003-2 DC/Vario tolerate only ±5% supply tolerance (tighter than the Neo models' ±10%), so size and regulate the PSU accordingly; there is no mains switch or thermal cut-out on the motor.

Can it be mounted inside an instrument enclosure, and what duty-cycle constraints apply?

Yes — 0.7 kg, 116×116×62 mm, IP30, 48 dB — but the enclosure must allow natural-convection airflow since cooling is passive and surfaces exceed 70 °C. Ambient 5–40 °C, max. 2000 m altitude, pollution degree 2. After vapor-laden processes run 30 min with gas ballast open; before shutdown run 5–10 min with open vacuum connection.

What is not in the base delivery and what should I stock for maintenance?

The factory-sealed pump only — the G 1/8" silencer, gas-ballast valve kits, purge gas nozzle with filter, RS-485/USB cables, OmniControl/handheld unit and service/overhaul kits are accessories. Plan diaphragm/valve overhaul using original kits (~8000 h wear life); the ex-factory closure seal must not be damaged or warranty is void.

Dimensional Drawings & Technical Documentation

Dimensional drawings

MVP 003-2 DC — drawing 1 MVP 003-2 DC — drawing 2 MVP 003-2 DC — drawing 3
performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
MVP 003-2 DC — product leaflet
Datasheet ·623,2 КБ ·4 pp.
View PDF
PDF
MVP 003-2 DC — instruction manual mvp 003 2 dc
Manual ·2,5 МБ ·42 pp.
View PDF