Shimadzu DSC 60 Plus Series
Shimadzu DSC 60 Plus Series — Thermal analyzers.
The DSC-60 Plus is a heat-flux differential scanning calorimeter with a measured temperature range of -140 to 600 °C and a calorimetric range of ±150 mW. It is the base, manual-loading member of the DSC-60 Plus Series, distinguished from the DSC-60A Plus by the absence of the 24-position autosampler. It is used to measure transition enthalpies and temperatures of materials under programmed heating and cooling.
Full specifications
| Calorimetric range | ±150 mW (DSC-60 Plus) |
| Measured temperature range | -140 to 600 °C (DSC-60 Plus) |
| Autosampler capacity (DSC-60A Plus) mfr | 24 samples/tray (DSC-60A Plus) |
| Autosampler capacity (DTG-60A / DTG-60AH) mfr | 24 samples/tray (DTG-60A / DTG-60AH) |
| Weight | 28 kg (DSC-60 Plus) |
| Weight (DSC-60A Plus) mfr | 31 kg (DSC-60A Plus) |
| Weight (DTG-60 / DTG-60A) mfr | 35 kg (DTG-60 / DTG-60A) |
| Weight (DTG-60H / DTG-60AH) mfr | 40 kg (DTG-60H / DTG-60AH) |
| Power consumption (DTG-60 / DTG-60A, 50/60 Hz) mfr | 1300 VA (DTG-60 / DTG-60A, 50/60 Hz) |
| Power consumption (DTG-60H / DTG-60AH, 50/60 Hz) mfr | 1500 VA (DTG-60H / DTG-60AH, 50/60 Hz) |
| Noise level | less than 0.5 μW (DSC-60 Plus) |
Description
Construction and series positioning
- The DSC-60 Plus is a single-furnace heat-flux DSC; the DSC-60A Plus is the same calorimetric platform with a built-in 24-sample autosampler tray (31 kg vs 28 kg).
- The DTG-60/60H/60A/60AH are separate TG/DTA instruments (ambient to 1100 °C or 1500 °C, 35–40 kg, 1300–1500 VA) and are not DSC variants; they appear in the same document only as related models.
- No certificates or application notes were supplied; performance claims below are limited to the factory specification sheet.
Behavior under load and in different modes
- Calorimetric range ±150 mW sets the maximum measurable heat-flow difference; samples whose transition enthalpy exceeds this at the programmed rate must be reduced in mass or scan rate.
- Noise is specified as less than 0.5 µW, which defines the smallest detectable heat-flow step and therefore the practical detection limit for weak transitions.
- Measured temperature range -140 to 600 °C is the only operating window given; no curve points or mode-specific (heating/cooling/isothermal) data were provided, so rate-dependent behavior cannot be quantified from the available facts.
Installation, connection and control
- The document digest contains no sections or actionable engineering facts; installation, electrical supply, purge-gas and control details are therefore not available from the supplied material and must be taken from the full instruction manual before commissioning.
Integration & Operating Notes
The calorimetric range is the full-scale heat-flow difference the instrument can record. Samples with large enthalpies at the chosen heating rate can saturate the signal; reduce sample mass or scan rate so the peak stays inside ±150 mW, otherwise the peak shape and onset temperature are invalid.
The measured temperature range is the only operating window stated for this model. Exceeding either limit is outside the specified measurement range and risks invalid results or damage to the furnace and sensor; the cooling medium required to reach -140 °C is not described in the supplied digest.
The attached document digest (c160-e006) contains no sections or actionable facts, so calibration, sensor cleaning and reference-material schedules are not available here. Request the complete instruction manual to set maintenance intervals and error-code handling before putting the unit into routine use.
Selection & Integration Q&A
Pick the DSC-60 Plus for manual sample loading and lower bench weight (28 kg). Choose the DSC-60A Plus when unattended runs of up to 24 samples per tray are needed; it weighs 31 kg and shares the same calorimetric platform.
The DTG-60/60H/60A/60AH are separate TG/DTA instruments (ambient to 1100 or 1500 °C, 1300–1500 VA), not accessories of the DSC-60 Plus. They are listed as related models only; no coupled DSC-TG configuration is described in the supplied facts.
Only the measurement window -140 to 600 °C and the 28 kg mass are specified. The supplied document digest has no sections on ambient conditions, cooling medium or duty cycle, so these must be confirmed from the full instruction manual.
The supplied facts list no accessories, cables or consumables. The autosampler tray belongs to the DSC-60A Plus, not this model. Reference materials, cooling accessories and cables must be confirmed against the full manual and order list.