Shimadzu EHF E Series
Shimadzu ·Made in Japan · In Active Production

Shimadzu EHF E Series

Shimadzu EHF E Series — Testing machines with Weight 940 kg.

The EHF-E Series is a line of electric-hydraulic servo fatigue testing machines with frame capacities of 50, 100, and 200 kN. The k1 modification provides ±25 mm crosshead travel, while the k2 offers ±50 mm; both are available in all three capacities. These machines are used for dynamic and static testing of materials and components under controlled force or displacement.

Weight
940 kg

Full specifications

Core Performance & Functional Specifications
Max. dynamic test force mfr ±50 kN (EHF-EV051k1, EHF-EV051k2)
Max. dynamic test force mfr ±100 kN (EHF-EV101k1, EHF-EV101k2)
Max. dynamic test force mfr ±200 kN (EHF-EV200k1, EHF-EV200k2)
Max. static test force mfr ±60 kN (EHF-EV051k1, EHF-EV051k2)
Max. static test force mfr ±120 kN (EHF-EV101k1, EHF-EV101k2)
Max. static test force mfr ±240 kN (EHF-EV200k1, EHF-EV200k2)
Actuator stroke mfr ±25 mm (EHF-EV051k1, EHF-EV101k1, EHF-EV200k1)
Actuator stroke mfr ±50 mm (EHF-EV051k2, EHF-EV101k2, EHF-EV200k2)
Capacity mfr 50 kN (EHF-E 50 kN frame)
Capacity mfr 100 kN (EHF-E 100 kN frame)
Capacity mfr 200 kN (EHF-E 200 kN frame)
Frame rigidity mfr 0.0012 mm/kN (EHF-E 50/100 kN frame)
Frame rigidity mfr 0.00065 mm/kN (EHF-E 200 kN frame)
Max. dynamic test force mfr ±50 kN (EHF-UV050k1A, EHF-UV050k2A)
Max. dynamic test force mfr ±100 kN (EHF-UV100k1A, EHF-UV100k2A)
Max. dynamic test force mfr ±200 kN (EHF-UV200k1A, EHF-UV200k2A)
Max. static test force mfr ±60 kN (EHF-UV050k1A, EHF-UV050k2A)
Dimensions, Weight & Mechanical Design
Weight 840 kg (EHF-EV051k1, Standard column)
EHF-EV051k2, Standard column: 900 kg · EHF-EV101k1, Standard column: 850 kg · EHF-EV101k2, Standard column: 910 kg · EHF-EV200k1, Standard column: 880 kg · EHF-EV200k2, Standard column: 940 kg
Column length mfr Standard + 400 mm (EHF-E all capacities)

Description

Construction and Series Positioning

The EHF-E Series comprises three frame capacities: 50 kN, 100 kN, and 200 kN. Each capacity is available in two crosshead travel variants: k1 (±25 mm) and k2 (±50 mm). The 50 kN and 100 kN frames share a rigidity of 0.0012 mm/kN, while the 200 kN frame is stiffer at 0.00065 mm/kN. Standard column configurations are offered, with weights ranging from 840 kg (EHF-EV051k1) to 940 kg (EHF-EV200k2). This series is distinct from other Servopulser variants such as the EHF-U, EHF-L, and EHF-JF, which have different force and stroke characteristics.

Behavior Under Load

The maximum dynamic test force equals the frame capacity: ±50 kN, ±100 kN, or ±200 kN. Static test force is higher, at ±60 kN, ±120 kN, or ±240 kN respectively. The k2 variant provides double the crosshead travel of the k1, making it suitable for tests requiring larger displacements. No digitized curve points are available for this model, so dynamic performance characteristics cannot be further detailed from the provided facts.

Installation and Operation

Specific installation, connection, and control details are not included in the available document digest. The digest only lists the scope of the Servopulser Series and does not contain actionable engineering facts for the EHF-E. Therefore, integration and operating notes below are limited to general inferences from the specifications.

Integration & Operating Notes

Mounting
Heavy frame requires stable foundation

With weights between 840 kg and 940 kg depending on model, the machine must be installed on a rigid, level floor capable of supporting the load and absorbing dynamic forces during testing. Ensure adequate clearance for crosshead travel and specimen handling.

Factory Specification Sheet
Process Limits
Do not exceed maximum dynamic or static forces

The maximum dynamic test force is ±50 kN, ±100 kN, or ±200 kN depending on frame capacity, and the maximum static test force is ±60 kN, ±120 kN, or ±240 kN. Exceeding these limits may damage the machine or invalidate test results.

Factory Specification Sheet
Process Limits
Crosshead travel limits test amplitude

The k1 variant provides ±25 mm crosshead travel, while the k2 provides ±50 mm. Test amplitudes must be planned within these limits to avoid over-travel and potential equipment damage.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the k1 versus the k2 variant of the EHF-E?

Choose k1 (±25 mm travel) for tests requiring smaller displacements and higher rigidity needs; choose k2 (±50 mm travel) for larger amplitude tests. Both are available in 50, 100, and 200 kN capacities.

What are the force capacity and rigidity differences between the 50/100 kN and 200 kN frames?

The 50 kN and 100 kN frames have a rigidity of 0.0012 mm/kN, while the 200 kN frame is stiffer at 0.00065 mm/kN. Dynamic forces are ±50 kN, ±100 kN, and ±200 kN respectively.

What maintenance and accessories are required for the EHF-E?

No maintenance schedule or accessory list is provided in the available documents. Consult the instruction manual for service intervals and optional accessories such as grips and fixtures.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
c225-e029
Datasheet ·68,7 МБ ·72 pp.
View PDF