Shimadzu ICPMS-2030
Shimadzu ·Made in Japan · In Active Production

Shimadzu ICPMS-2030

Shimadzu ICPMS-2030 — Elemental analyzers.

The Shimadzu ICPMS-2030 is a quadrupole inductively coupled plasma mass spectrometer with a 27 MHz, 1.4 kW high-frequency plasma source, a mini torch, coaxial nebulizer, and electronically cooled cyclone spray chamber. Its octopole collision cell and 5–260 m/z range support trace multi-element analysis in environmental, clinical, and industrial laboratories. This configuration is the base model for routine ultratrace elemental determination.

Full specifications

Core Performance & Functional Specifications
Wavelength range 200 to 900 nm (UV-VIS measurement, p.18)
Scan speed mfr Medium (UV-VIS measurement, p.18)
Average count mfr 512 (SALD-7500nano, p.13)
Water level mfr Middle stage (SALD-7500nano, p.13)
Average fiber diameter mfr 16 nm (after 3rd treatment, p.5)
Average fiber diameter mfr 14 nm (after 4th treatment, p.5)
Average fiber diameter mfr 12 nm (after 5th treatment, p.5)
Dimensions, Weight & Mechanical Design
Sampling pitch mfr 1.0 nm (UV-VIS measurement, p.18)

Description

Construction and architecture

Integration & Operating Notes

Electrical
RF generator rated 27 MHz, max 1.4 kW — verify facility power

The high-frequency power supply operates at 27 MHz with a maximum output of 1.4 kW. Facility electrical service, grounding, and cooling must be sized for this RF load; exceeding the rated output or operating without adequate cooling risks generator damage and unstable plasma.

Factory Specification Sheet
Process Limits
Mini torch and cooled cyclone chamber define sample aerosol path

The coaxial nebulizer feeds the electronically cooled cyclone spray chamber and mini torch. Sample uptake rate, solvent volatility, and dissolved-solids load must be kept within the torch and chamber tolerance; high matrix or high-organic samples may require dilution or additional gas flows not specified in the supplied facts.

Factory Specification Sheet
Control & I/O
Collision cell mode selection affects interference suppression

The octopole collision cell can be operated with collision/reaction gases to reduce polyatomic interferences. Method development must define cell gas and mode per element; no automatic interlock or sequencing details were supplied in the available documentation.

Factory Specification Sheet
Maintenance
No maintenance schedule or consumables list supplied

The supplied facts contain no service intervals, error codes, or consumable part numbers. Torch, nebulizer, and interface cones are typical wear items for this instrument class, but replacement intervals must be taken from the manufacturer's manual, which was not provided.

Factory Specification Sheet

Selection & Integration Q&A

What adjacent system components must be matched to the ICPMS-2030?

The 27 MHz, 1.4 kW RF supply requires facility power and cooling sized to that load. Sample introduction uses a coaxial nebulizer, cooled cyclone chamber, and mini torch; replacement parts must match these exact configurations. No controller or autosampler compatibility data were supplied.

What mounting and duty-cycle limits apply to this instrument?

The supplied facts give no mounting, environmental, or duty-cycle limits. The 1.4 kW RF generator and cooled spray chamber imply continuous cooling and stable laboratory conditions are needed, but exact ambient temperature, humidity, and duty ratings must be obtained from the manual.

What maintenance items and accessories are not included in the base delivery?

No consumables, cables, or accessory list was provided. Torch, nebulizer, and interface cones are typical wear parts for this instrument class, but part numbers and service intervals are absent from the supplied facts and must be confirmed with the manufacturer.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
Solutions for Cellulose Nanofibers
Datasheet ·10,3 МБ ·26 pp.
View PDF