The Nexera XS Inert is a high-pressure liquid chromatograph with a maximum allowable pressure of 105 MPa, featuring inert sample-contact surfaces and standard 3-solvent internal rinsing. It is designed for corrosion-resistant, inert analysis of samples and mobile phases, ensuring excellent chromatographic separation performance.
Direct drop-in replacements
Full specifications
Description
Construction and Positioning
The Nexera XS Inert is a complete HPLC system distinguished by its inert flow path, which minimizes interaction between sample/mobile phase and system surfaces. With a maximum allowable pressure of 105 MPa, it supports high-resolution separations using small-particle columns. Standard internal rinsing with three solvents (3 dil) reduces carryover and maintains performance. ### Behavior Under Load
The system operates up to 105 MPa, enabling the use of sub-2 µm particle columns for fast, efficient separations. The inertness of wetted surfaces ensures compatibility with a wide range of mobile phases, including those containing corrosive salts or reactive compounds, without compromising chromatographic integrity. ### Installation and Operation
Installation requires appropriate laboratory infrastructure, including a stable power supply and proper waste handling for solvents. The internal rinsing feature simplifies maintenance and ensures reproducible results.
Integration & Operating Notes
Operating above the maximum allowable pressure of 105 MPa can damage the column, tubing, and pump seals, leading to leaks or failure. Always verify pressure limits of columns and components in the flow path.
The standard internal rinsing (3 dil) helps prevent carryover and salt buildup. Establish a rinsing protocol after each analysis or at the end of the day to maintain inertness and prolong component life.
While the system is designed for inertness, verify that all mobile phases and samples are compatible with the materials used in the flow path to avoid degradation or contamination.
Selection & Integration Q&A
Choose the XS Inert when analyzing samples with corrosive or reactive compounds that may interact with standard stainless steel surfaces. Its inert flow path and 105 MPa pressure limit make it ideal for high-resolution separations requiring maximum inertness. For less demanding applications, standard Nexera models may suffice.
The system requires compatible fittings and tubing rated for at least 105 MPa. Ensure the mobile phase degassing and waste lines are properly connected. The internal rinsing feature needs three solvent lines. Verify that the detector and autosampler are compatible with the inert flow path.