Shimadzu Quantasep Trusty 100
Shimadzu ·Made in Japan · In Active Production

Shimadzu Quantasep Trusty 100

Shimadzu Quantasep Trusty 100 — Laboratory balances.

The Shimadzu Quantasep Trusty 100 is a multi-use chromatography system with two feed pumps (six lines each), ten fractionation lines, and three column connections, supporting forward, reverse, and bypass flow. It operates at up to 100 psi with a 7 mL hold-up volume and flow rates of 1–100 mL/min. It is intended for automated liquid handling and fractionation in laboratory process development, with UV, conductivity, and pH monitoring.

Full specifications

Core Performance & Functional Specifications
Column volume mfr 50 mL (SuperFlo 50)
Column volume mfr 100 mL (SuperFlo 100)
Column volume mfr 250 mL (SuperFlo 250)
Column volume mfr 500 mL (SuperFlo 500)
Column volume mfr 1000 mL (SuperFlo 1000)
Column volume mfr 1500 mL (SuperFlo 1500)
Column volume mfr 2 L (SuperFlo 2L)
Column volume mfr 3 L (SuperFlo 3L)
Column volume mfr 5 L (SuperFlo 5L)
Column volume mfr 7.5 L (SuperFlo 7.5L)
Column volume mfr 10 L (SuperFlo 10L (5 cm bed))
Column volume mfr 10 L (SuperFlo 10L (10 cm bed))
Column volume mfr 20 L (SuperFlo 20L)
Column volume mfr 30 L (SuperFlo 30L)
Column volume mfr 40 L (SuperFlo 40L)
Column volume mfr 50 L (SuperFlo 50L)
Column volume mfr 60 L (SuperFlo 60L)
Column volume mfr 70 L (SuperFlo 70L)
Column volume mfr 80 L (SuperFlo 80L)
Column volume mfr 90 L (SuperFlo 90L)
Column volume mfr 100 L (SuperFlo 100L)
Column volume mfr 150 L (SuperFlo 150L)
Column volume mfr 350 L (SuperFlo 350L)
Dimensions, Weight & Mechanical Design
Bed height/depth mfr 3.5 cm (SuperFlo 50–1500 mL)
Bed height/depth mfr 5 cm (SuperFlo 2L–10L)

Description

Construction and positioning

Integration & Operating Notes

Process Limits
System pressure must not exceed 100 psi

Exceeding 100 psi risks damage to tubing, fittings, and sensors. The pressure sensor range is 0–100 psi with ±1 psi accuracy, so the system should be operated with a safety margin below the limit, especially when columns or filters may cause pressure spikes.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Quantasep Trusty 100 over higher-end models in the series?

Choose the Trusty 100 when inline buffer dilution and mixing are not required. Higher-end models offer those features. The Trusty 100 provides multi-use flow path, two pumps, ten fractionation lines, and three column connections, suitable for applications without inline buffer preparation.

What are the requirements for connecting columns and detectors to the Trusty 100?

The system supports three columns with forward, reverse, or bypass flow. Wetted materials include polypropylene fittings, PTFE diaphragms, and stainless steel sensor components. Ensure columns and detectors are compatible with these materials and the 100 psi pressure limit. Flow rate range is 1–100 mL/min.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
c190-e351
Datasheet ·5,3 МБ ·8 pp.
View PDF