Shimadzu SPM 9700HT Plus
Shimadzu ·Made in Japan · In Active Production

Shimadzu SPM 9700HT Plus

Shimadzu SPM 9700HT Plus — Microscopes.

The SPM 9700HT Plus is a scanning probe microscope (SPM) from Shimadzu configured for high-throughput, large-area imaging with a standard 10 µm × 10 µm × 1 µm XYZ scanning range. It distinguishes itself within the series by offering multiple optional scan ranges up to 125 µm × 125 µm × 7 µm, while maintaining 0.2 nm XY and 0.01 nm Z resolution. It is intended for nanoscale surface topography and property mapping in materials and life science research where sample sizes up to 8.0 mm must be accommodated.

Full specifications

Core Performance & Functional Specifications
Resolution 0.2 nm (SPM-9700HT Plus)
Observation modes (* Option) mfr Contact/Dynamic Phase/Force Modulation, Lateral (* Option)
Sample types accommodated mfr Zeolite, Blended Polymer, Platinum Iridium Film,
Observation speed (HT scanner, Nano3D MappingTM Fast (Optional)) mfr Ultra-fast observations achieved by improving pr (HT scanner, Nano3D MappingTM Fast (Optional))
Physical property mapping time (Nano3D Mapping Fast (Optional)) mfr Significantly reduced compared to the previous m (Nano3D Mapping Fast (Optional))
Observation condition configuration (NanoAssist) mfr Operating points and gain values configured auto (NanoAssist)
Head slide mechanism mfr Cantilever does not need to be reconfigured; nex
Data analysis functions mfr Surface roughness, particle data analysis, morph
Automated support functions mfr M2M, IoT, Artificial Intelligence (AI)
Max sample size mfr ø24 mm × 8 mm (SPM-9700HT Plus)
Vibration damping mechanism mfr Mounted on SPM unit (SPM-9700HT Plus)
Scanner scan range (Middle Range Scanner (optional)) mfr 30 μm (Middle Range Scanner (optional))
Scanner scan range (Wide Range Scanner (optional)) mfr 125 μm (Wide Range Scanner (optional))
Scanner scan range (Deep-Type Scanner (optional)) mfr 55 μm (Deep-Type Scanner (optional))
Scanner scan range (Narrow Range Scanner (optional)) mfr 2.5 μm (Narrow Range Scanner (optional))
Dimensions, Weight & Mechanical Design
Cantilever mounting (Cantilever master (Optional)) mfr Easy and secure mounting of the cantilever (Cantilever master (Optional))
Interfaces, Connections & Control
X/Y-axis control (Scan controller) mfr ±211 V Always 16-bit resolution V (Scan controller)
Standards, Safety & General Data
Scanner scan range (HT Scanner (standard)) mfr 10 μm (HT Scanner (standard))

Description

Construction and positioning

Integration & Operating Notes

Mounting
Magnetic sample securing limits sample types

Samples must be magnetic or mounted on a magnetic holder to be secured. Non-magnetic samples require alternative fixation methods such as adhesive tabs or mechanical clamps, which may affect flatness and vibration characteristics. Ensure the sample surface is clean and flat for reliable scanning.

Factory Specification Sheet
Process Limits
Maximum sample size 8.0 mm

The sample stage accepts specimens up to 8.0 mm in any dimension. Exceeding this may cause collision with the probe or scanner, potentially damaging the tip and scanner. Verify sample dimensions before mounting.

Factory Specification Sheet
Environment
Vibration isolation recommended for nanoscale imaging

SPM measurements at sub-nanometer resolution are sensitive to mechanical vibrations and acoustic noise. Install the system on a rigid, vibration-isolated table and in an acoustically quiet area. Enclosures may be needed for demanding applications.

General SPM installation guidelines

Selection & Integration Q&A

When should I choose the SPM 9700HT Plus over other models in the Shimadzu SPM series?

Choose the 9700HT Plus when you need a balance of large scan range (10 µm standard) and high resolution (0.2 nm XY, 0.01 nm Z) for samples up to 8.0 mm. For larger areas, consider optional scanners up to 125 µm; for ultra-high resolution on small areas, the 2.5 µm scanner is available. Base models may lack the high-throughput scanner or sample size capacity.

What are the requirements for the sample and sample holder?

Samples must be secured by magnet, so they need to be magnetic or mounted on a magnetic holder. Maximum sample size is 8.0 mm. Non-magnetic samples require alternative fixation, which may affect stability. Ensure the sample surface is compatible with the probe approach and scanning.

What environmental conditions are necessary for optimal performance?

Install the SPM on a vibration-isolated table in a temperature-controlled room with low acoustic noise. Avoid air drafts and direct sunlight. While not specified in the provided facts, typical SPM installations require stable temperature (±1°C) and humidity control to minimize drift during long scans.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
c147-e020
Datasheet ·625,8 КБ ·4 pp.
View PDF
PDF
c147-e021
Datasheet ·4,3 МБ ·20 pp.
View PDF