Shimadzu Tescan Clara
Shimadzu Tescan Clara — Microscopes.
The Tescan Clara is an ultra-high-resolution SEM (UHR-SEM) built around the BrightBeam field-free column, configured for SE and energy-filtered/angle-selective BSE detection. Its MultiVac low-vacuum mode with water vapor extends imaging to non-conductive or beam-sensitive specimens that would otherwise require coating. It serves as the primary high-resolution imaging station in materials and life-science labs, with Essence software handling acquisition and detector configuration.
Full specifications
Description
Construction and series positioning
- BrightBeam field-free SEM column: a fully electrostatic/electromagnetic lens design without immersion field at the specimen, keeping the sample region field-free for magnetic or sensitive specimens. - Detector set: secondary electron (SE) plus backscattered electron (BSE) channels, the BSE path being both energy-filtered and angle-selective — this is the distinguishing detection configuration of this model. ### Behavior in different modes and media
- High-vacuum operation is the default UHR imaging condition; MultiVac low-vacuum mode introduces water vapor as the imaging gas, enabling charge compensation on insulating specimens. - Energy-filtered BSE allows material contrast to be tuned by selecting the energy window of collected backscattered electrons; angle-selective BSE adds crystallographic/orientation contrast. - No digitized curve points or measured resolution values were supplied, so no quantitative performance envelope is asserted here. ### Installation, connection and control
- Control and acquisition run through the Essence software platform; detector selection, vacuum mode and imaging parameters are set from this environment.
Integration & Operating Notes
MultiVac operation depends on a water-vapor supply to the specimen chamber; the engineer must provide and regulate this medium, and specimens or processes incompatible with water vapor exposure must be imaged in high vacuum instead.
SE, energy-filtered BSE and angle-selective BSE selection, together with high-vacuum versus MultiVac mode, are configured through the Essence platform, so integration with the lab network and operator training should center on this software environment.
Because the BrightBeam column is field-free at the specimen, working distance and stage geometry must respect the column's specified clearance; exceeding the allowed specimen height or tilt risks collision with pole pieces and invalid imaging. Confirm limits in the site-preparation manual before mounting large or tilted samples.
Selection & Integration Q&A
Specimen height and tilt must stay within the field-free column's clearance; oversized or heavily tilted samples risk pole-piece collision. Quantitative clearance and duty-cycle figures are not in the supplied facts and must be confirmed in the manual.