Shimadzu Tescan Mira
Shimadzu Tescan Mira — Microscopes.
The Tescan Mira is a Schottky field-emission scanning electron microscope (FEG SEM) configured for high-resolution surface and sub-surface imaging with a wide detector suite (SE, BSE, EDS, CL, Raman, STEM, EBSD, WDS). It uses Essence software with In-Flight Beam Tracing and an intermediate lens, and supports SingleVac and optional MultiVac vacuum modes. It serves as a flexible analytical platform for materials characterization where both topographic contrast and microanalysis are required.
Full specifications
Description
Construction and positioning
- The Mira is a FEG SEM built around a Schottky field-emission source, delivering high brightness and stable probe current for imaging and microanalysis. - Detector complement includes SE, BSE, EDS, CL, Raman, STEM, EBSD and WDS, allowing simultaneous topographic, compositional and crystallographic data acquisition. - Wide Field Optics and In-Flight Beam Tracing with an intermediate lens support flexible beam control across magnifications. ### Behavior under load and in different modes
- Vacuum operation supports SingleVac mode as standard, with MultiVac available as an option; this affects allowable sample types and pump-down behavior. - Beam deceleration is optional, enabling low-voltage operation for charge-sensitive or beam-sensitive specimens. - The Essence 3D Collision Model is part of the software environment, supporting simulation and interpretation of electron–specimen interactions. - No digitized curve points were supplied, so quantitative performance envelopes (resolution vs. voltage, probe current ranges) must be taken from the factory specification sheet. ### Installation, connection and control
- Control and acquisition run through Essence software; no separate controller hardware details were provided in the digests. - Detector and accessory integration (EDS, EBSD, WDS, Raman, CL, STEM) must be planned at the system level, as port availability and geometry are not specified in the supplied facts.
Integration & Operating Notes
SingleVac is standard and MultiVac is optional; the selected vacuum mode determines the permissible chamber pressure and therefore which samples (porous, outgassing, hydrated) can be imaged without contamination or pump-down delays. Confirm the installed mode before accepting a sample.
FEG sources and high-voltage electronics are sensitive to supply stability and grounding quality.
All acquisition, detector selection, and beam control are managed through Essence, including the 3D Collision Model. Detector and accessory integration must be configured within this environment, so third-party detectors require Essence-compatible interfaces.
The maintenance schedule in the instruction manual must be followed to avoid emission drift or chamber contamination; consumables and cables are not included in base delivery.
Selection & Integration Q&A
Detectors and accessories (EDS, EBSD, WDS, Raman, CL, STEM) must be Essence-compatible and mechanically fit the available ports. Site power, cooling, and grounding must meet the site-preparation manual; no controller or drive details are given, so integration is planned at the system level.