Shimadzu TOC L Series
Shimadzu TOC L Series — TOC analyzers.
The TOC L Series is a combustion-type total organic carbon analyzer with a vertical tube furnace and NDIR detection, available in standalone and PC-controlled configurations. It covers a working range from 4 µg/L to 35,000 mg/L IC and 5 µg/L to 10,000 mg/L TN, with model-dependent features such as built-in LCD, USB data export, and autosampler compatibility. It is used for laboratory water quality monitoring, including priority sampling with autosamplers and COD/BOD conversion.
Full specifications
| Measurement range | 4 μg/L - 25,000 mg/L TCï¼ |
| Capacity mfr | 120 – 320 g (AP W Series) |
| Response time for trace measurements (as low as 1 mg) mfr | approximately 2 s (as low as 1 mg) |
| Automatic door opening/closing time (AP W-AD model) mfr | approximately 1 s (AP W-AD model) |
| CSN/CPN mfr | 50 |
| COD/BOD conversion mfr | Function available (TOC-V CSH/CSN only) |
| Built-in LCD mfr | Black and white |
| Number and type of data saved (standalone model) mfr | 200 samples |
| Output of data saved (standalone model) mfr | Not available |
| Printer mfr | Built-in printer (thermal) |
| PC connection mfr | 232 C |
| Autosampler cover mfr | Fitted cover |
| Kit for small sample volumes mfr | 8 mL |
| Halogen scrubber for high-salt samples (B-type halogen scrubber) mfr | No option available |
| Weight | TOC main unit: W440 x D525 x H460 mmï¼Approx. 40 kg TN unit added: W600 x D525 x H460 mm, Approx. 48 kg |
| External dimensions, weight mfr | TOC main unit: W440 x D525 x H460 mmï1⁄4Approx. |
| Power consumption | . 20,000 Wh Approx |
| Power consumption (Weekly integrated value) Note 2 mfr | . 20,000 Wh Approx |
| Minimum display mfr | 0.1 mg (AP W Series) |
Description
Construction and series positioning
The TOC L Series is a combustion TOC analyzer platform. This model supports both standalone and PC operation, with a TFT color LCD on some variants and USB connectivity for data export. The series offers a 36% reduction in weekly power consumption compared to earlier models (approx. 12,700 Wh vs 20,000 Wh). ### Behavior under load and media
- Measurement ranges: IC 4 µg/L – 35,000 mg/L; TN 5 µg/L – 10,000 mg/L; TC 50 µg/L – 30,000 mg/L (for CSN/CPN variants). The wide dynamic range allows direct analysis of both trace and high-concentration samples, though high-salt samples require the optional high-salt combustion tube kit and halogen scrubber to prevent corrosion and interference. - The instrument uses a carrier gas (likely high-purity air or oxygen) and detects CO2 via NDIR. Carrier gas problem detection is available on some variants, alerting the user to gas supply issues that would otherwise cause invalid results. - Priority water sampling when using an autosampler can reduce measurement time by up to 30 seconds per sample (with 3 measurements), improving throughput for large batches. ### Installation, connection, and operation
- Power consumption is approximately 12,700 Wh per week (integrated value), indicating moderate energy use. The instrument requires a stable power supply; no specific voltage is given in the facts, but typical laboratory equipment operates on 100–240 V AC. - PC connection is via RS232C or USB, depending on the model. Standalone models can save measurement results for 2,000 samples or more (all results and peak data) and calibration curves; data can be exported to a USB memory stick. A built-in thermal printer is available on some variants, or a PC USB printer can be used (sold separately). - The autosampler cover is a two-part design that simplifies adding vials during a run. The instrument supports validation support via PC software (CPH/CPN variants).
Integration & Operating Notes
Samples with high salt content can rapidly degrade the standard combustion tube and cause halogen interference. The high-salt sample combustion tube kit and B-type halogen scrubber must be installed for such matrices; otherwise, measurement drift and tube failure may occur.
The instrument can detect carrier gas supply problems and should be configured to flag or halt measurements when gas pressure or flow is out of range. This prevents reporting data from incomplete combustion. The detection function is available on this model and should be enabled in the method settings.
The combustion tube and halogen scrubber are consumables that degrade with use, especially with high-salt samples. Replace them according to the maintenance schedule in the instruction manual. Failure to do so leads to baseline noise, low recovery, and potential damage to the NDIR detector. Keep spare kits on hand for uninterrupted operation.
Selection & Integration Q&A
Choose this model if you need a wide measurement range (IC up to 35,000 mg/L) and options like high-salt kits and USB data export. Select a CSH/CSN variant if you require a built-in LCD and printer; choose CPH/CPN for PC-controlled operation with validation support.
The instrument supports RS232C or USB connection to a PC. For standalone models, data can be exported to a USB memory stick. Ensure the PC has the appropriate driver and software (e.g., for CPH/CPN validation). A USB printer can be connected for direct printing.