Shimadzu UV 1900I Plus
Shimadzu ·Made in Japan · In Active Production

Shimadzu UV 1900I Plus

Shimadzu UV 1900I Plus — Spectrophotometers.

Double-beam UV-Vis spectrophotometer with 1 nm resolution and LO-RAY-LIGH grating technology, enabling high-speed scanning up to 29,000 nm/min. Supports photometric, spectrum, quantitation, kinetics, time-course, and bio-method modes with JP/USP/EP compliance. Designed for multi-user laboratories requiring rapid, accurate spectral analysis and network connectivity.

Full specifications

Core Performance & Functional Specifications
Blank solution absorbance N3 -0.00002 Abs (UV-1900i Plus)
Blank solution absorbance N4 0.00002 Abs (UV-1900i Plus)
Blank solution absorbance N6 -0.00003 Abs (UV-1900i Plus)
Blank solution absorbance N7 0.00001 Abs (UV-1900i Plus)
Long-path cell path lengths 10, 20, 30, 50, 70 mm (P/N 204-23118-01)
Basic measurement modes 6 (UV-1900i Plus)
Triple-pass sipper sample volume 1.5 mL (P/N 206-23790-52)
50-mm sipper sample volume 5.0 mL (P/N 206-23790-56)
Photometric accuracy (correlation coefficient) mfr 0.9998 (UV-1900i Plus)
Maximum number of wavelengths in photometric mode (Photometric mode) mfr up to (Photometric mode)
Electrical, Power & Drive Specifications
Power consumption reduction in sleep mode (Shutdown/Wakeup function vs normal operation) mfr more than 85 % (Shutdown/Wakeup function vs normal operation)
Interfaces, Connections & Control
Wavelength range (UV-1900i Plus, spectrum display) mfr 300.0-700.0 nm (UV-1900i Plus, spectrum display)
Materials, Media & Process Compatibility
Recycled resin content 50 % (UV-1900i Plus)
Standards, Safety & General Data
Standard sipper sample volume 2.0 mL (P/N 206-23790-51)
Blank absorbance standard deviation 0.000025 Abs (UV-1900i Plus)

Description

Construction and Architecture

Integration & Operating Notes

Control & I/O
Requires LabSolutions UV-Vis software for full functionality

The instrument is controlled via LabSolutions UV-Vis software, which must be installed on a compatible PC. Ensure the PC meets software requirements and is connected via appropriate interface. Without the software, advanced modes and data handling may be limited.

Factory Specification Sheet
Electrical
Network connectivity requires additional memory

To enable network connectivity, additional memory must be installed. Plan for this if the instrument will be integrated into a networked laboratory environment for data transfer or remote monitoring.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the UV-1900i Plus over other double-beam spectrophotometers in the Shimadzu lineup?

Choose the UV-1900i Plus when you need high-speed scanning (up to 29,000 nm/min) and multi-mode operation (photometric, spectrum, quantitation, kinetics, time-course, bio-methods) with pharmacopeia compliance. For routine single-wavelength measurements, a simpler model may suffice.

What are the requirements for connecting the UV-1900i Plus to a laboratory network?

Network connectivity is supported but requires additional memory to be installed. Ensure the instrument is configured with the necessary memory and connected via Ethernet or compatible interface. LabSolutions UV-Vis software must be installed on a networked PC for data transfer.

What maintenance and accessories are required for the UV-1900i Plus, and what is not included in the base delivery?

Routine maintenance includes lamp replacement and cuvette cleaning. The base delivery typically includes the instrument and standard accessories, but LabSolutions UV-Vis software, additional memory for networking, and replacement lamps are usually ordered separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
c101-e181
Datasheet ·10,6 МБ ·16 pp.
View PDF