Waters ACQUITY Premier UPLC System
Waters ACQUITY Premier UPLC System — Chromatographs with Flow rate 2 milliliter/minute, Max pressure 103.4 megapascal.
The ACQUITY Premier UPLC System is a binary or quaternary high-pressure liquid chromatograph with a flow-through needle injector and inert MaxPeak HPS sample path, rated to 15,000 psi and 2.0 mL/min. It distinguishes itself within the ACQUITY series by combining active solvent pre-heating, sub-0.002% carryover, and eCord column tracking in a single 711 mm high enclosure. It serves as the separation engine in analytical workflows requiring ultra-high-pressure gradients and low-adsorption surfaces for sensitive analytes.
Full specifications
| Flow rate | 2.0 mL/min |
| Max pressure | 15000 psi |
| Column temperature | 40 C |
| Injection type mfr | Flow-Through Needle, Fixed Loop |
| Sample Flow Path mfr | Inert (MaxPeak HPS Technology) |
| Sample Carryover mfr | ≤0.002% |
| Sample Compartment mfr | 4 to 40 C |
| Pump Options mfr | Binary, Quaternary |
| Solvent Conditioning mfr | Active pre-heating as standard |
| Column Tracking mfr | eCord Technology column information management t |
| Column Capacity mfr | Six columns up to 150 mm length, up to 4.6 mm in |
| Maximum Sample Capacity mfr | 8,064 (with Sample Organizer) |
| Detector Options mfr | TUV Detector, PDA eλ Detector, FLR Detector, Cha |
| External Control mfr | Empower Software, MassLynx Software, waters_conn |
| Height | 711 mm |
| Width | 343 mm |
| Depth mfr | 71.2 cm (28.0 in.) |
| pH Range mfr | 1 to 12.5 |
Description
Construction and positioning
- The system integrates a high-pressure pump (binary or quaternary), an autosampler with flow-through needle and fixed loop, a thermostatted column compartment (40 °C setpoint, six columns up to 150 mm × 4.6 mm I.D.), and a detector bay compatible with TUV, PDA eλ, FLR, charged aerosol, RI, ELS, or mass spectrometers. - The sample flow path is fully inert via MaxPeak High Performance Surfaces, reducing adsorption of metal-sensitive compounds; sample carryover is specified at ≤0.002%. - Physical envelope: 711 mm height × 343 mm width × 712 mm depth, designed for benchtop installation. ### Behavior under load and media
- Maximum operating pressure is 15,000 psi (≈103.4 MPa) at flow rates up to 2.0 mL/min; the pH range of 1 to 12.5 accommodates acidic and basic mobile phases. - Active pre-heating of the solvent is standard, stabilizing retention times under gradient conditions; the sample compartment is thermostatted from 4 to 40 °C. - The flow-through needle design minimizes carryover without a separate needle wash, supporting high-throughput sequences. ### Installation, control, and operation
- External control is via Empower, MassLynx, or waters_connect software; the system requires connection to a control workstation and solvent lines. - eCord technology automatically reads and archives column usage data, simplifying column tracking and method transfer. - The system supports up to 8,064 samples when equipped with the optional Sample Organizer, enabling extended unattended runs.
Integration & Operating Notes
Operating above the pressure or flow limit risks seal failure, column damage, and invalid chromatographic results. The limit applies to the entire flow path, including the column and detector cell; ensure method gradients are validated against the system pressure ceiling.
Outside this range, the inert MaxPeak surfaces and column hardware may degrade, leading to metal leaching and compromised peak shape. Buffer selection and pH adjustment must be verified before use, especially with high-concentration salts.
The eCord chip on each column must be read by the system and registered in Empower, MassLynx, or waters_connect to archive usage. Without registration, column history and performance data are not recorded, which may affect method transfer and compliance.
The 8,064-sample capacity requires the optional Sample Organizer; base delivery includes only the standard sample compartment. Plan for additional bench space and power connections if extended capacity is needed.
Selection & Integration Q&A
Choose this model when you need inert sample paths for metal-sensitive analytes, sub-0.002% carryover, and active solvent pre-heating in a single integrated system. For lower pressure or simpler binary-only needs, other ACQUITY models may suffice.
The system supports TUV, PDA eλ, FLR, charged aerosol, RI, ELS detectors, and mass spectrometers. Control is via Empower, MassLynx, or waters_connect; ensure the chosen detector and software are configured for the flow rates and pressures used.
The Sample Organizer for 8,064-sample capacity is optional. Column tracking requires eCord-equipped columns. Routine maintenance includes pump seals, needle, and tubing; these consumables and the Sample Organizer must be ordered separately.