The ACQUITY UPLC PDA Detector is a photodiode array detector with a light-guiding UPLC intelligent flow cell (500 nL, 10 mm path) for spectral profile detection in UPLC systems. It covers 190 nm and beyond with ±1 nm accuracy and ≤0.8 μL dispersion, distinguishing it by its analytical flow cell. It serves as the primary detector for acquiring full UV-Vis spectra in method development and routine analysis.

Full specifications

Core Performance & Functional Specifications
Detector type Photodiode Array (PDA) Detector
Wavelength range 190 nm
Wavelength accuracy mfr ±1 nm (via patented 1 Erbium filter)
Linearity range mfr Deviation at 2.0 AU ≤5%, propylparaben, at 257 n
Optical resolution mfr 1.2 nm
Digital resolution mfr 0.6 nm/pixel to 500 nm
Drift mfr ≤1.0 x 10 –3 /AU/hour/°C with analytical flow ce
Sampling rate mfr Up to 80 points/s
Light source mfr Prealigned, intelligent technology Deuterium lam
Dispersion volume mfr ≤0.8 μL (Analytical flow cell); ≤1.5 μL (High se
Flow cell design mfr Light-guiding UPLC intelligent technology flow c
Flow cell volume mfr 500 nL (analytical flow cell)
Wetted materials mfr 316 stainless-steel, fused silica, Teflon AF, PE
Pressure limit mfr 1000 psi (all flow cells)
Dimensions, Weight & Mechanical Design
Path length mfr 10 mm (analytical flow cell)
Width mfr 34.3 cm (13.5 inches)
Height mfr 19.4 cm (7.6 inches)
Depth mfr 60.7 cm (23.9 inches)
Operating Conditions, Environment & Protection
Noise ±3 μAU, 230 nm, 2 points/s, 2 s, wavelength compensation 310 to 410 nm, 90:10 water/methanol (2D channel with analytical flow cell)

Description

Construction and Positioning

Integration & Operating Notes

Process Limits
Flow cell pressure must not exceed 1000 psi

Exceeding 1000 psi may damage the flow cell and compromise the light-guiding path. Ensure system pressure is regulated and monitored, especially when the detector is placed after high-pressure stages or when using narrow-bore tubing.

Factory Specification Sheet
Process Limits
Wetted materials limit solvent compatibility

The analytical flow cell uses 316 stainless steel, fused silica, Teflon AF, and PEEK. Avoid solvents that attack these materials, such as strong acids or bases, to prevent leaks and baseline noise.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this PDA detector instead of a single-wavelength UV detector?

Choose this PDA for spectral profile detection, peak purity, and multi-wavelength acquisition. A single-wavelength detector is sufficient for routine quantitation at one wavelength and offers simpler method transfer.

What maintenance is required and what consumables are not included?

The deuterium lamp is prealigned and intelligent; replacement is straightforward. No other maintenance schedule or consumables are specified in the provided facts. Refer to the manual for lamp replacement intervals and accessories.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve

Click drawing to inspect vector dimensions

Technical documentation