Waters Aura Plus System
Waters Aura Plus System — Particle size analyzers.
The Aura Plus System is an imaging-based particle size analyzer with 4x and 20x objectives and a 1.0 pixel/µm spectral resolution, configured for 96-well and 24-well plate formats. It detects particles from >1 µm to <5 mm (96-well) or <14 mm (24-well) and reads a 96-well plate in about 1 minute per sample. It is used for automated particle sizing and morphological analysis in laboratory workflows.
Direct drop-in replacements
Full specifications
| Spectral resolution | 1.0 pixel/µm |
| Imaging area mfr | 24.6 mm 2 (96-well); 158.9 mm 2 (24-well) |
| Optics mfr | 4x and 20x objectives |
| Minimum volume mfr | 5 μL (assay dependent) |
| Detectable size range mfr | From >1 μm (ECD) to <5 mm (ECD) on 96-well; <14 |
| BMI read time mfr | 1 minute/sample |
| FMM read time mfr | 30 seconds/sample |
| Software mfr | Particle VUE TM 5.x all-in-one software suite fo |
Description
Construction and positioning
The Aura Plus System is a benchtop imaging particle analyzer that combines two magnifications (4x and 20x) with a large imaging area: 24.6 mm² for 96-well plates and 158.9 mm² for 24-well plates. The minimum sample volume is 5 µL, assay dependent. ### Measurement behavior
The system covers a detectable size range from >1 µm to <5 mm on 96-well plates and up to <14 mm on 24-well plates, using ECD (equivalent circular diameter) as the size metric. Spectral resolution is 1.0 pixel/µm. Read times are 1 minute per sample for BMI and 30 seconds per sample for FMM, enabling moderate-throughput plate-based analysis. ### Software and operation
All image acquisition and analysis are controlled by the Particle VUE™ 5.x all-in-one software suite, with an optional Security Pack for regulated environments.
Integration & Operating Notes
The minimum volume is 5 µL, but this is assay dependent; lower volumes may not fill the imaging area adequately, leading to incomplete data. Verify that the assay volume meets or exceeds this threshold before running plates.
On 96-well plates the detectable size range is from >1 µm to <5 mm (ECD), while on 24-well plates it extends to <14 mm (ECD). Select the plate format according to the expected particle size distribution to avoid truncation of large particles.
Selection & Integration Q&A
The system is a benchtop laboratory instrument; typical operating conditions for laboratory equipment (e.g., 15–30 °C, <80% RH non-condensing) should be assumed unless the manual states otherwise. Continuous operation is possible with read times of 1 minute/sample (BMI) or 30 seconds/sample (FMM).