Waters Fraction Manager - Analytical
Waters ·Made in USA · In Active Production

Waters Fraction Manager - Analytical

Waters Fraction Manager - Analytical — Chromatographs with Flow rate 2.2 milliliter/minute, Max pressure 2.07 megapascal.

The Fraction Manager - Analytical is a benchtop fraction collector for analytical HPLC, with a 13.6 µL internal delay volume and a 0.1–5.0 mL/min flow range. It operates at up to 300 psi and maintains the fraction compartment from 4.0 to 40.0 °C, settable in 0.1 °C increments. It is used to collect precise fractions from analytical-scale separations under controlled temperature.

Flow rate
2.2 milliliter/minute
Max pressure
2.07 megapascal

Full specifications

Core Performance & Functional Specifications
Flow rate 2.2 mL/min
Max pressure 300 psi
Column temperature 40.0 °C
Operating HPLC flow range mfr 0.1 to 5.0 mL/min with high flow needle
pH operating range mfr pH 2–12
Internal delay volume mfr 13.6 μL*
Needle move time mfr 0.7 s Vessel to vessel with needle above vessel;
Carryover mfr <0.15% with rinse enabled
Fraction compartment temperature mfr Range 4.0–40.0 °C, settable in 0.1 °C increments
Integrated leak management mfr Leak sensor as standard, and safe leak handling
Operating temperature mfr Range 4–40 °C
Storage temperature mfr -40 °C–60 °C
External control mfr Empower® or MassLynx® Software with FractionLynx
External communications mfr Ethernet interfacing via RJ45 connection to host
Event inputs/outputs mfr Inject start, auxiliary output
Dimensions, Weight & Mechanical Design
Height 27 cm
Weight 20 kg
Width 34 cm
Depth mfr 71 cm (28 inches)
Electrical, Power & Drive Specifications
Voltage mfr 90 to 264 VAC
Frequency mfr 47 to 63 Hz
Materials, Media & Process Compatibility
Primary wetted material mfr MP35N, PEEK, Teflon, DLC, and Tefzel
Operating Conditions, Environment & Protection
Audible noise mfr <60 db
Humidity mfr 20% to 80% non-condensing

Description

Construction and positioning

Integration & Operating Notes

Process Limits
Do not exceed 300 psi system pressure

The fraction manager is rated for a maximum pressure of 300 psi (2.07 bar). Exceeding this limit may damage the internal flow path or cause leaks. Ensure the HPLC system upstream does not generate pressures above this value at the fraction manager inlet.

Factory Specification Sheet
Process Limits
Keep mobile phase pH between 2 and 12

The wetted materials (MP35N, PEEK, Teflon, DLC, Tefzel) are compatible with pH 2–12. Operating outside this range can cause corrosion or degradation, leading to leaks or sample contamination.

Factory Specification Sheet
Electrical
Accepts worldwide AC mains without selection

The power supply operates from 90 to 264 VAC at 47 to 63 Hz, so no voltage selection is required. Ensure the protective earth connection is reliable and that the supply can deliver the required current.

Factory Specification Sheet
Control & I/O
Use inject start signal to synchronize fraction collection

The event input for inject start must be wired to the autosampler or system controller to trigger fraction collection at the correct time. Without this signal, fractions may be offset, reducing recovery.

Factory Specification Sheet
Maintenance
Enable rinse to keep carryover below 0.15%

Carryover is specified as <0.15% only when the rinse function is enabled. Ensure the rinse solvent is appropriate for the application and that the rinse cycle is included in the method.

Factory Specification Sheet
Environment
Install in a location with stable ambient temperature

The fraction compartment can maintain 19.0 °C below ambient, but the ambient must be within 4–40 °C and humidity 20–80% non-condensing. Avoid direct sunlight and drafts to ensure temperature stability.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the Fraction Manager - Analytical instead of a preparative-scale fraction collector?

Choose this model for analytical HPLC flows of 0.1–5.0 mL/min and pressures up to 300 psi. For higher flow rates or pressures, a preparative-scale collector is required.

What are the requirements for connecting the Fraction Manager to an existing HPLC system?

It requires an Ethernet connection to a host PC running Empower or MassLynx with FractionLynx, and an inject start signal from the autosampler. The flow path must not exceed 300 psi or pH 2–12.

What are the ambient temperature and humidity limits for operating the Fraction Manager?

Operate between 4 and 40 °C and 20–80% non-condensing humidity. The fraction compartment can be set from 4.0 to 40.0 °C but can only cool to 19.0 °C below ambient.

Dimensional Drawings & Technical Documentation

Dimensional drawings

Fraction Manager - Analytical — drawing 1

Click drawing to inspect vector dimensions

Technical documentation

PDF
Waters Fraction Manager - Analytical Instrument Driver Version 1.60 Certificate of Structu
Manual ·354,4 КБ ·1 pp.
View PDF